  • Page 1 Water-i.d. ® water testing equipment User Manual Manuel d’utilisation Manual de usuario Gebrauchsanleitung Manuale dell’utente ® Electronic Pool Water Measurement...
  • Page 3 CONTENT | CONTENU | CONTENIDO INHALT | CONTENUTO Delivery Content Changing Batteries Switching n / ff General Advices/Important 7 – 9 Tablet & Liquid Mode Switch 10 – 13 Quick Start Guide 14 – 17 ZERO 18 – 19 TEST | pH 20 –...
  • Page 4: Delivery Content

    DELIVERY CONTENT 1 x PoolLab 1.0 1 x Light shield 3 x AAA Batteries 1 x Crushing | Stirring Rods 1 x 10ml syringe 1 x User guide 20 x Phenol Red Photometer tablets 20 x DPD N° 1 Photometer tablets 10 x DPD N°...
  • Page 5 BATTERIES | PILES | PILAS BATTERIEN | BATTERIE change | chargement | cambio wechseln | cambiamento No rechargeable batteries! | Pas de piles rechargeables! ¡No hay baterías recargables! | Keine aufladbaren Batterien! Niente batterie ricaricabili! 3 x AAA...
  • Page 6 SWITCH ON | ALLUMER | ENCENDER EINSCHALTEN | ACCENDERE 00:02 ZERO On/Off button can also be used to skip countdown during measurement (not recommended) Le bouton Marche/Arrêt peut être également utilisé pour ignorer le compte à rebours lors de la mesure (non recommandé) El botón de On/Off también se puede utilizar para cancelar la cuenta atrás durante la medición (no se recomienda) Die On/Off Taste kann auch zum Abbrechen des Countdowns...
  • Page 7 ADVICES | CONSEILS | CONSEJOS HINWEISE | CONSIGLI Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! Do not touch reagent tablets! Toujours utiliser des pastilles de qualité PHOTOMETRE! Ne jamais utiliser des pastilles de qualité "RAPID" ! Ne touchez pas les pastilles PHOTOMETER avec les mains! ¡Usar siempre tabletas...
  • Page 8 IMPORTANT | IMPORTANTE | WICHTIG Detergent waterproof (IP68 ) ZERO It is important to clean the device after each measurement to get rid of any reagent residues! Il est important de nettoyer le dispositif après chaque mesure pour éliminer les résidus de réactifs! Es importante limpiar el dispositivo después de cada medición para deshacerse de cualquier residuo de reactivo! Es ist wichtig, das Gerät nach jeder Messung zu reinigen, um...
  • Page 9 IMPORTANT | IMPORTANTE | WICHTIG Do not leave the device in the sun! Ne laissez pas l'appareil au soleil! ¡No deje el dispositivo al sol! Lassen Sie das Gerät nicht in der Sonne liegen! Non lasciare il dispositivo al sole! The PoolLab is also suitable for saltwater pools / salt electrolysis pools! Le PoolLab convient également aux piscines d'eau salée /...
  • Page 10 NEW! Tablet Mode – Liquid Mode Tablettenmodus – Flüssigreagenz Modus Modo Tableta – Modo Reactivo Líquido Mode Comprimés – Mode Réactif Liquide Modalità Compressa – Modalità Reagente Liquido pH | fCl2 | tCl | cCl | Br | ClO | O Scan the QR-code to watch our intstruction video...
  • Page 11 Tablet Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO Liquid Mode: Press And Hold ZERO + Power Button ZERO ZERO ZERO...
  • Page 12 From firmware version 72 onwards, you have the option of measuring the following parameters with tablets as well as with liquid reagents: pH, chlorine, chlorine dioxide, ozone and bromine. You can choose between two measurement settings in the unit: Tablets and Liquid reagents. You can switch between the modes by pressing and releasing the ZERO &...
  • Page 13 A partir de la version 72 du firmware, vous avez la possibilité de mesurer les paramètres suivants aussi bien avec des pastilles qu'avec des réactifs liquides: pH, chlore, dioxyde de chlore, ozone et brome. Vous pouvez choisir entre deux réglages de mesure dans l'appareil: Comprimés et Réactifs liquides.
  • Page 14 QUICK START GUIDE Kurzanleitung Guía De Inicio Rápido Guide De Démarrage Rapide Guida Rapida Scan the QR-code to watch our intstruction video...
  • Page 15 Hold & Press To Switch On 3 x AAA 00:02 ZERO START: Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO Put On Lightshield ZERO ZERO ZERO ZERO...
  • Page 16 Remove Lightshield Reagent(s) For Your Test (Refer To Chapter In Manual) ZERO ZERO Put On Lightshield Use Force! ZERO ZERO Completely Residue Dissolved Shortcut Await For Your Countdown Test (Refer To Chapter In Manual) ZERO ZERO...
  • Page 17 Empty & Clean For Next Test: Take 10ml waterproof (IP68 ) ZERO 10 ml *If Device Was Not Switched *If Device Was Switched Off, Off, Start From Step 8 Start From Step 3 End Of Quick Start Guide | Ende der Kurzanleitung | Fin de la Guia Rapida Fin du guide de démarrage rapide | Fine della guida rapida...
  • Page 18 ZERO waterproof (IP68 ) ZERO Take 10 ml Water Sample 10 ml No Reagents! waterproof (IP68 ) ZERO ZERO ZERO ZERO...
  • Page 19 Only 1 time per test batch Une seule fois par lot de test Sólo una vez por lote de prueba Nur 1 x pro Testreihe Solo una volta per test in batch The "ZERO" step (page 18) is only necessary once after switching on. Make sure that the water to be measured does not (!) contain any tablet/reagent in the cuvette and that the light protection cover is in place.
  • Page 20 Liquid Mode: Tablet Mode: 6.50 – 8.40 pH 6.50 – 8.40 pH Phenol Red Liquid* Phenol Red Photometer *not part of standard equipment waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO...
  • Page 21 Tablet Or Liquid? (p. 10) Phenol Red Photometer ZERO! (p.18) 6 x Phenol ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
  • Page 22 ZERO The Total Alkalinity value has to be minimum 50 mg/l to obtain a correct pH value. La valeur totale de l'alcalinité doit être au minimum de 50 mg/l pour obtenir une valeur de pH correcte. El valor de alcalinidad debe ser superior a 50 mg/l para obtener un pH correcto.
  • Page 24 Chlorine Chlore Cloro Chlor Cloro Tablet Mode: Liquid Mode: 0.00 – 8.00 ppm (mg/l) 0.00 – 4.00 ppm (mg/l) DPD N°1 Photometer DPD 1A + DPD 1B + DPD 3C Liquid* DPD N°3 Photometer Tablet 0.00 8.00 0.00 4.00 4.00 2.00 *not part of standard equipment waterproof...
  • Page 25 Tablet Or Liquid? (p. 10) DPD N°1 Photometer 3 x DPD 1A + ZERO! (p.18) 3 x DPD 1B ZERO ZERO Use Force! Completely Dissolved ZERO ZERO Residue...
  • Page 26 Tablet Or Liquid? (p. 10) DPD N°3 Photometer 3 x DPD 3C ZERO ZERO ppm = mg/l Use force! Completely Dissolved ZERO ZERO Residue...
  • Page 27 ZERO Total Chlorine is measured directly after free Chlorine without emptying the cuvette. The DPD 3 tablet is added to the sample water which already contains the DPD 1 tablet (dissolved). Combined Chlorine is calculated as Total Chlorine minus free Chlorine. The free chlorine measurement must be taken within 1 minute after dissolving the tablet.
  • Page 28 El cloro total se mide directamente después de cloro libre, sin necesidad de vaciar la cubeta. La tableta DPD 3 se añade a la cubeta en la que la tableta DPD 1 ya está disuelta. El cloro combinado se calcula a partir de cloro total menos cloro libre.
  • Page 30 Cyanuric Acid Acide Nurique Ácido Cianúrico Cyanursäure Acido Cianurico 0 – 160 ppm (mg/l) CYA–Test Photometer waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
  • Page 31 1 x CYA–Test Use Force! Photometer Completely Dissolved ZERO ZERO Residue ZERO ZERO...
  • Page 32 Alkalinity Alcalinité Alcalinidad Alkalinität Alcalinità 0 – 200 ppm (mg/l) CaCO Alkalinity–M Photometer waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO...
  • Page 33 Use Force! 1 x Alkalinity-M ZERO! (p.18) Photometer Completely Dissolved ZERO ZERO ZERO Residue ZERO ZERO...
  • Page 34 Active Oxygen Oxygène actif Oxígeno activo Aktivsauerstoff Ossigeno Attivo (MPS) 0.0 – 30.0 ppm (mg/l) DPD N°4 Photometer* 10.0 30.0 *not part of standard equipment waterproof (IP68 ) ZERO take 10 ml water sample waterproof (IP68 ) 10 ml ZERO...
  • Page 35 1 x DPD N°4 Use Force! Photometer* ZERO! (p.18) Completely Dissolved ZERO ZERO ZERO Residue ZERO ZERO...
  • Page 36 Chlorine Dioxide Dioxyde de Chlore Dióxido de cloro Chlordioxid Biossido di Cloro Tablet Mode: Liquid Mode: 0.00 – 15.00 ppm (mg/l) 0.00 – 7.60 ppm (mg/l) DPD 1A + 1B Liquid* DPD N°1 Photometer Tablet Glycine* Glycine* 0.00 11.40 0.00 7.60 5.00 3.00...
  • Page 37 Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used. Otherwise (only Chlorine Dioxide present), please follow procedure "B". Seulement si votre échantillon d'eau contient du chlore avec du dioxyde de chlore (les deux désinfectants utilisés), la procédure suivante «A»...
  • Page 38 With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely Dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely Dissolved ZERO...
  • Page 39 Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely Dissolved ZERO ZERO Residue 8 /6 ZERO ZERO...
  • Page 40 Bromine Brome Bromo Brom Bromo Liquid Mode: Tablet Mode: 0.00 – 18.00 ppm (mg/l) 0.00 – 9.00 ppm (mg/l) DPD 1A + DPD 1B Liquid* DPD N°1 Photometer Tablet Glycine* Glycine* 0.00 18.00 0.00 9.00 9.00 4.00 *not part of standard equipment waterproof (IP68 ) ZERO...
  • Page 41 Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure "A" needs to be followed and Glycine reagent needs to be used. Otherwise (only Bromine present), please follow procedure "B" Seulement si votre échantillon d'eau contient du chlore avec du Brome (les deux désinfectants utilisés), la procédure suivante «A»...
  • Page 42 With Chlorine | Mit Chlor | Con Cloro Avec Du Chlore | Con il Cloro Glycine* Use Force! Completely dissolved ZERO ZERO Residue Tablet Or Liquid? (p. 10) DPD N°1 Photometer Use Force! 3 x DPD 1A + 3 x DPD 1B Completely dissolved ZERO...
  • Page 43 Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 Photometer 3 x DPD 1A + Use Force! 3 x DPD 1B Completely Dissolved ZERO ZERO Residue 8 /6 ZERO ZERO...
  • Page 44 Ozone Ozono Ozon Liquid Mode: Tablet Mode: 0.00 – 5.40 ppm (mg/l) 0.00 – 2.70 ppm (mg/l) DPD 1A + DPD 1B DPD N°1 Photometer Tablet DPD 3C Liquid* DPD N°3 Photometer Tablet Glycine* Glycine* 0.00 5.40 0.00 2.70 2.50 1.30 *not part of standard equipment waterproof...
  • Page 45 Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure "B" needs to be followed and Glycine reagent needs to be used. Otherwise (only Ozone present), please follow procedure "A". Seulement si votre échantillon d'eau contient du chlore avec de l‘...
  • Page 46 Without Chlorine | Ohne Chlor Sin Cloro | Sans Chlore | Senza Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + 3 x DPD 3C Completely Dissolved ZERO...
  • Page 47 With Chlorine | Mit Chlor Con Cloro | Avec Du Chlore | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + Completely 3 x DPD 3C Dissolved ZERO ZERO...
  • Page 48 With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro 0 ml ZERO 10 ml waterproof (IP68 ) ZERO Glycine* Use Force! Completely Dissolved ZERO ZERO Residue...
  • Page 49 With Chlorine | Avec Du Chlore Con Cloro | Mit Chlor | Con il Cloro Tablet Or Liquid? (p. 10) DPD N°1 + DPD N°3 Use Force! Photometer 3 x DPD 1A + 3 x DPD 1B + Completely 3 x DPD 3C Dissolved ZERO ZERO...
  • Page 50 Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (LR) 0.00 – 2.90 ppm (mg/l) Hydr. Peroxide LR Photometer* 0.00 1.45 2.90 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 )
  • Page 51 1 x Hydr. Peroxide Use force! Photometer* completely dissolved ZERO ZERO residue ZERO ZERO...
  • Page 52 Hydrogen Peroxide Peroxyde d'Hydrogène Peróxido de Hidrógeno Wasserstoffperoxid Perossido di Idrogeno (HR) 0 – 200 ppm (mg/l) Hydr. Peroxide HR Photometer | Acidifying PT *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 )
  • Page 53 1 x Acidifying Use Force! ZERO ZERO Completely Dissolved Residue 1 x Hydr. Peroxide Photometer* Use Force! ZERO ZERO Completely Dissolved Residue ZERO ZERO...
  • Page 54 Total Hardness Dureté Totale Dureza Total Gesamthärte Durezza Totale 0 – 500 ppm (mg/l) CaCO POL20TH1 | POL10TH2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO Take 10 ml Water Sample ZERO! (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
  • Page 55 POL20TH1* POL10TH2* *shake before use! 10 x ZERO ZERO ZERO ZERO...
  • Page 56 Calcium Hardness Dureté Calcique Dureza de Calcio Kalziumhärte Durezza del Calcio 0 – 500 ppm (mg/l) CaCO POL20CaH1 | POL20CaH2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
  • Page 57 POL20CaH1* POL20CaH2* *shake before use! 10 x 10 x ZERO ZERO ZERO ZERO...
  • Page 58 ZERO ZERO ZERO ZERO...
  • Page 59 Hardness Conversion | Conversion de dureté | Conversión de dureza | Härte- Umrechnung | Conversione di durezza CaCO °dH* °e* °f* mval S 4,3 mg/l mmol/l (KH) (CH) (DC) 0.01 0.056 0.07 0.02 1 mg/l CaCO 10.0 1 mmol/l K S 4,3...
  • Page 60 Urea Urée Harnstoff 0.1 – 2.5 ppm (mg/l) Dechlor | PL Urea 1 | PL Urea 2 Ammonia N°1 | Ammonia N° 2 *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml...
  • Page 61 1 x Dechlor ZERO ZERO Use Force! ZERO ZERO Completely Dissolved Residue PL Urea *Shake Before Use! ZERO ZERO...
  • Page 62 PL Urea *Shake Before Use! ZERO ZERO ZERO ZERO...
  • Page 63 4 14 Ammonia N° 1 ZERO ZERO Ammonia N° 2 ZERO ZERO...
  • Page 64 ZERO ZERO If the sample contains free chlorine, a „Dechlor“ tablet has to be added to the vial, before adding PL Urea 1 and PL Urea 2. Ammonia N° 1 only dissolves entirely after Ammonia N° 2 was added. Ammonia and chloramines will be detected together.
  • Page 65 Si la muestra contiene cloro libre, hay que añadir una pastilla de "Dechlor" al vial, antes de añadir PL Urea 1 y PL Urea 2. Ammonia N°1 no se disuelve por completo hasta que agregue Ammonia Nº 2. El amoníaco y cloraminas se detectan juntos. Por consiguiente, el resultado mostrado es la suma de los dos.
  • Page 66 PHMB 5 – 60 ppm (mg/l) PHMB Photometer* *not part of standard equipment waterproof (IP68 ) ZERO ZERO ZERO! Take 10 ml Water Sample (p.18) waterproof (IP68 ) 10 ml ZERO ZERO...
  • Page 67 1 x PHMB Photometer Use Force! Completely Dissolved ZERO ZERO Residue ZERO ZERO...
  • Page 68 It is imperative that you clean the objects used for the measurement and come into contact with the sample water containing the reagent (cuvette, lid, stirring rod) thoroughly with a brush, water and then with distilled water, otherwise the measuring equipment may turn blue over time. Alkalinity values (M) <>...
  • Page 69 Reinigen Sie unbedingt die für die Messung verwendeten und mit dem mit Reagenz versetzten Messwasser in Berührung gekommenen Gegenstände (Küvette, Deckel, Rührstab) gründlich mit einer Bürste, Wasser und anschließend mit destilliertem Wasser, da sich ansonsten das Messbesteck mit der Zeit blau verfärben kann. Alkalinitätswerte (M) <>120 mg/l und Calzium-Härte-Werte <>200 mg/l können zu Messwertabweichungen führen.
  • Page 70 OR-UR (DILUTION) | OR-UR (VERDÜNNUNG) OR-UR (DILUCIÓN) | OR-UR (DILUZIONE) OR = Overrange / UR = underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5ml (or 1ml) sample water plus 5ml (9ml) distilled water.
  • Page 71 ERROR CODES | CODES D'ERREUR | CÓDIGOS DE ERROR | FEHLERCODES | CODICI DI ERRORE BAT!: Change batteries | Changer les piles | Cambiar las pilas | Batterien wechseln | Cambiare le batterie Err02: (too dark) Clean measurement chamber or dilute sample | (Trop sombre) Nettoyer la chambre de mesure ou diluer l'échantillon | (Demasiado oscura) Limpie la cámara de medición o diluya la muestra | (zu dunkel) Messkammer...
  • Page 72 TROUBLESHOOT | DÉPANNAGE | SOLUC. PROBLEMAS FEHLERBEHEBUNG | RISOLUZIONE DIE PROBLEMI 1) 01.01.1970: The date on the PoolLab is set to 01.01.1970 when delivered, after each battery change and after each update. Please reconnect to the LabCOM app so that the smartphone date is adopted again.
  • Page 73 4) Aplastar las pastillas enérgicamente con la varilla agitadora. La cubeta no se rompe 5) El cloro total puede mostrarse más bajo que el cloro libre dentro de las tolerancias indicadas en este manual. 6) Humedad en la pantalla: Puede ocurrir si la humedad residual en la carcasa se condensa debido al agua fría durante la inmersión.
  • Page 74 CHANGING THE CUVETTE | CHANGER LA CUVETTE CAMBIAR LA CUBETA | KÜVETTENWECHSEL CAMBIANDO LA CUVETTA 90° ZERO ZERO 90° ZERO ZERO...
  • Page 75 ACCESSORIES | ACCESSOIRES | ACCESORIOS ZUBEHÖR | ACCESSORI Reagents | Réactifs | Reactivos | Reagenzien | Reagenti POL01-Nf 20/20/10/10/10 Phenol Red / DPD N° 1 / DPD N° 3 / -Test / Alkalinity-M Photometer TbsPph50 50 x Phenol Red Photometer TbsPD150 50 x DPD N°...
  • Page 76 SOFTWARE & APP | LOGICIELS & APP SOFTWARE & APLICACIÓN Bluetooth ON Bluetooth OFF ZERO www.poollab.org Windows/MacOS:...
  • Page 77 TECHNICAL DATA | DONNÉES TECHNIQUES DATOS TÉCNICOS | TECHNISCHE DATEN DATI TECNICI www.poollab.org MSDS msds.water-id.com Cloud labcom.cloud 530 nm / 570 nm / 620 nm LED: 3 x AAA (1.5 V, LR03) 300 sec. ï 5 - 45°C IP 68 (1 h / 1.2 m) Developed in Germany Produced in PRC...
  • Page 78 TOLERANCES | TOLÉRANCES TOLERANCIAS | TOLERANZEN | TOLLERANZE Active Oxygen (MPS) | Oxygène actif (MPS) Oxígeno activo (MPS) | Aktivsauerstoff (MPS) Ossigeno Attivo (MPS) Range ± 0.0 – 5.0 0.5 ppm (mg/l) 5.0 – 15.0 1.3 ppm (mg/l) 15.0 – 25.0 3.8 ppm (mg/l) 25.0 –...
  • Page 79 TOLERANCES | TOLÉRANCES TOLERANCIAS | TOLERANZEN | TOLLERANZE Calcium Hardness | Dureté Calcique Dureza de Calcio | Kalziumhärte Durezza del Calcio Range ± 0 – 25 8 ppm (mg/l) 25 – 100 22 ppm (mg/l) 100 – 300 34 ppm (mg/l) 300 –...
  • Page 80 TOLERANCES | TOLÉRANCES TOLERANCIAS | TOLERANZEN | TOLLERANZE Chlorine Dioxide | Dioxyde de Chlore Dióxido de cloro | Chlordioxid Biossido di Cloro Range ± 0.00 – 2.00 0.19 ppm (mg/l) 2.00 – 6.00 0.48 ppm (mg/l) 6.00 – 10.00 1.43 ppm (mg/l) 10.00 –...
  • Page 81 TOLERANCES | TOLÉRANCES TOLERANCIAS | TOLERANZEN | TOLLERANZE Ozone | Ozono | Ozon Range ± 0.00 – 1.00 0.07 ppm (mg/l) 1.00 – 2.00 0.17 ppm (mg/l) 2.00 – 3.00 0.51 ppm (mg/l) 3.00 – 4.00 0.68 ppm (mg/l) 4.00 – 5.40 0.85 ppm (mg/l) Range ±...
  • Page 82 TOLERANCES | TOLÉRANCES TOLERANCIAS | TOLERANZEN | TOLLERANZE Total Hardness | Dureté Totale | Dureza Total Gesamthärte | Durezza Totale Range ± 0 – 30 3 ppm (mg/l) 30 – 60 5 ppm (mg/l) 60 – 100 10 ppm (mg/l) 100 –...
  • Page 83 DISPOSAL Device According to EC Directive 2002/ 96/EC, electronic devices must not be disposed of in normal domestic waste. The manu-facturer of this device, Water-i.d.® GmbH, Daimlerstr. 20, D-76344 Eggenstein will dispose of your PoolLab Photometer free of charge (not including costs of sending the device to us).
  • Page 84 UKCA Complaince Statement UK Conformity Assessed We, Water-i.d. GmbH Germany, hereby certify our responsibility, that the following product: PrimeLab 2.0 Photometer, is tested to and conforms with the essential test suites included in the following standards, which are in force within the UK: Standards Legislation Number Regulations 2016 (S.I.
  • Page 85 FCC PART 15 COMPLIANCE STATEMENT IC LICENCE-EXEMPT RSS COMPLIANCE STATEMENT This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 86 (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le...
  • Page 87 NOTES | NOTAS | NOTIZEN | NOTE...
  • Page 88: Certificate Of Compliance

    CERTIFICATE | CERTIFICAT | CERTIFICADO ZERTIFIKAT | CERTIFICATO CERTIFICATE OF COMPLIANCE We hereby certify that the device PoolLab 1.0® With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation. We confirm the device got factory-calibrated. Water-i.d.®...