Operation (continued)
4
Using the heater control
Pressing the heater button (4) will turn on or off the heat function. There is no speed setting for the heater blower. If you
□
put the heater in a standby mode (turn off by the main power button 6), the unit will hold the settings in the memory.
When the power is turned back on, the heater will turn on at the same settings.
When the heating function turns on, press and hold the heater button (4) for five seconds to enter temperature
□
adjustment mode. The LED indicator is red. In adjustment mode, the display (1) flashes (interval is 0.5 second). The
temperature setting range is between 62°F - 82°F - ON (17°C - 27°C - ON).
With the heater on, gently press and hold the main power button for five seconds to enter temperature converting mode.
□
The LED indicator flashes five times in red color then changes to green. In this converting mode, the display (1) flashes
(interval is 0.5 second). Press and hold the heater button (4) for five seconds to enter temperature adjustment mode.
Repeat the same process to convert Celsius temperature into Fahrenheit temperature.
To lock the heating function, with the main power button on, press and hold the heater button (4) for ten seconds. The log
□
lights flash six times to indicate that the heater function is locked. In this mode, there is no heating function but only glowing logs.
NOTE: After the heater function or power is shutoff the blower will continue to run for several minutes to cool the internal
components.
To unlock the heating function, press and hold the heater button (4) for ten seconds. The log lights flash six times and
□
then enter heating function mode.
1
5
Using the flame control
Press the flame button (5) to set the flames for different levels of flame height. These flame levels are shown in the display
□
(1). The flame settings are as follows:
Button Press
1st press
2nd press
3rd press
4th press
5th press
□ Regardless of the previous flame setting, when powered off by the main power button, the flames will come on in L4 mode
(High) when you turn the heater on.
□ To lock the flame function, with the flame in L4 mode, press and hold the flame button (5) for five seconds. The log lights flash
six times to indicate that the flame function is locked. In this mode, there are no flames but only glowing logs. Pressing the
flame button in sequence will set the logs for different levels of log brightness. The logs brightness levels are shown in the
display segment (1). The logs settings are as follows:
Button Press
1st press
2nd press
3rd press
4th press
5th press
□ To unlock the flame function, press and hold the flame button (5) for five seconds. The log lights flash six times and then both
flame lights and log lights turn on.
1
4
Flame Level
High
Medium
Low
Flames Off
All Off
Flame Level
Flames Off
Flames Off
Flames Off
Flames Off
All Off
5
Display Value
Fireplace Appearance
L4
Flames Highest, Logs Glow Highest
L3
Flames Medium, Logs Glow Medium
L2
Flames Low, Logs Glow Low
L1
Flames Off, Logs Glow Highest
None
Flames Off, Logs Off
Display Value
Fireplace Appearance
L4
Logs Glow Brightest
L3
Logs Glow Medium
L2
Logs Glow Low
L1
Logs Glow Brightest
None
Logs Off
6