5. Silencing (Pause mode)
If one wants to deliberately proactively silence the gas warning, for example to cook, sim-
ply press briefly on the button on the device. A double tone follows (high, low) and the
device is now silenced for 60 minutes. I.e. there is no radio signal to WiProIII / CAS III, no
acoustic signal from the internal piezo and no control of the siren output (output SIR+).
The LEDs possibly emit an alarm (see quick guide). The device then returns to normal op-
eration after 60 minutes. A double tone follows (high, low). Prematurely pressing on the
button immediately switches a load sound. For very high carbon monoxide concentration
(only with G.A.S.-pro III CO ) , the alarm has priority, and the piezo is not silenced.
6. Low Voltage Warning
If the operating voltage drops below the threshold of 11.1 V, then 3 tones sound 3 times
within one minute. Also a "weak battery" signal is acoustically emitted via a coupled
WiProIII / CAS III. The device then switches off, in order to prevent a deep discharging of
the battery. If the supply voltage is then restored, the device must be restarted.
7. Overtemperature Warning
If the temperature in the device exceeds 60° C, the device emits an acoustic warning (in-
creasing and decreasing intensity continual sound) and the status LEDs flash recurring in
all colours (red, green, magenta, blue, yellow, turquoise). No signal is emitted via a coupled
WiProIII / CAS III.