Page 20
ENGLISH
Symptom
Fault message appears on
controller display.
6.1
Service Technician Maintenance
This pump must be serviced by a professional service technician qualified in pool/spa installation. The following
procedures must be followed exactly. Improper installation and/or operation can create dangerous electrical
hazards, which can cause high voltages to run through the electrical system. This can cause property damage,
serious personal injury, and/or death. Improper installation and/or operation will void the warranty.
Blocked Impeller
Before servicing the pump, switch off the circuit breakers at the power source. Severe personal injury or death may
occur if the pump starts while your hand is inside the pump.
1.
Turn off the pump. Switch off the circuit breaker to the pump motor.
2.
Remove the lid and basket.
3.
Look inside the pump for debris. Remove any debris found inside.
4.
Replace the basket and lid.
5.
Switch on the circuit breaker to the pump motor.
6.
Turn on the pump, and see if the problem is solved.
7.
If the impeller is still blocked with debris and it is not possible to remove the debris using Steps 2 through 4, the
pump will need to be disassembled in order to access the inlet and outlet of the impeller.
Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how
to correct fault, contact Zodiac Technical Support at 800.822.7933. In Canada, call
1-888-647-4004
CAUTION
WARNING
Possible Cause/Solution
|
Installation & Operation Manual