Genius JA108 Instructions D'installation page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2. PROGRAMMING
The system uses two, six-digit codes that can be customised by the user. Each code can activate the relative
output relay, or both. To access the programming mode, turn the switch located on control card to the "ON"
position. The red LED on the keyboard will begin to flash.
2.1 CODE PROGRAMMING
1) Enter the channel on which to program the code: (1) or (2). The red LED on the keyboard will turn on.
2) Enter the code consisting of 1 to 6 digits. All the digits can also be the same number.
3) Enter (#) to store the code or (*) to quit the phase.
4) Repeat the sequence to change the code or to program the code for the other channel.
DO NOT USE TWO IDENTICAL CODES.
2.2 OPERATING PROGRAMMING
1) Enter (0). The red LED on the keyboard will turn on.
2) Enter the channel on which to program the code: (1) or (2).
3) Enter (3) to set the MONOSTABLE operating mode (impulse).
4) Enter (4) to set the BISTABLE operating mode (step-step).
5) Enter (5) to activate ONLY the relay relative to the channel (Channel 1 = Relay A; Channel 2 = Relay B)
6) Enter (6) to activate ALSO the relay relative to the other channel.
7) Enter (#) to store the code or (*) to quit the phase.
8) Repeat the sequence to change the settings or to program the operating mode of the other channel.
2.3 IMPULSE DURATION PROGRAMMING (IN MONOSTABLE OPERATING MODE)
1) Enter (7) to program the impulse duration on relay A or (8) to program the impulse duration on relay B.
2) The red LED on the keyboard will turn on.
3) Enter the time in seconds, consisting of two digits: 00 t 99 seconds.
4) The red LED on the keyboard will start flashing.
2.4 KEYBOARD LOCKOUT DURATION PROGRAMMING (AFTER THREE FALSE CODES)
1) Enter (9). The red LED on the keyboard will turn on.
2) Enter the time in seconds, consisting of two digits: 00 t 99 seconds.
3) The red LED on the keyboard will start flashing.
To exit the programming mode, turn the switch located on control card to the "OFF" position. Enter (#) the red
LED will turn off.
3. INSTALLATION (FIG. 1 PAG.1)
A) Keyboard
B) Control card
C) Programming switch
D) To other keyboards (max. 4)
E) Relay A contract output
F) Relay B contract output
G) Power supply: 24V~/ "
H) NC tear-proof tamper
J) Keyboard LED control for customised signals
4. OPERATION
The red LED flashes once to confirm that code 1 was entered and twice to confirm that code 2 was entered.
In the MONOSTABLE operating mode, after entering the code, the relative relay will be excited. It is
de-excited after the programmed impulse duration. The monostable operating mode is particularly su-
itable to control electric locks and automation units. In the BISTABLE operating mode, after entering
the code, the relative relay will be excited and then will be de-excited when the code is entered a se-
cond time. The bistable operating mode is ideal for turning anti-theft alarm units on and off. If you typed
a wrong code, a protection system locks out the keyboards for a time set in the programming mode.
It is possible to control the two LEDs on the keyboards for other signals. Just send a positive 12Vdc to terminal (7) to
turn on the red LED, and to terminal (8) to turn on the green LED (e.g. it is possible to display when the alarm system
turns on/off, or the status of the various areas, using the outputs N1-N4 or V-R on the terminals of the anti-theft units).
:
using the 12V positive
A = Green LED
B = Red LED
K) White
L) Red
M) Yellow
N) Black
O) Blue
P) Blue
7
00058I0223 - Rev. 6

Publicité

Table des Matières
loading

Produits Connexes pour Genius JA108

Ce manuel est également adapté pour:

A10801

Table des Matières