Pump in function but stopped Pump restarts by itself after the fault is
blinks red
Pump out of function
LED off
No power supply
If the fault cannot be remedied, please consult the specialist technician or the Wilo factory after-sales service.
11
Disposal
Damage to the environment and risks to personal health are avoided by the proper disposal and appropriate recycling of this product.
1. Use public or private disposal organisations when disposing of all or part of the product.
2. For more information on proper disposal, please contact your local council or waste disposal office or the supplier from whom you obtained the product.
Technical information subject to change without prior notice!
Fig. 1:
Diagnostic
Pump runs according its setting
Pump in standby
disappeared
Pump stopped (blocked)
No voltage on electronics
Fig. 2a:
n/¹/min
max
min
0
5
85 88
93
100
Cause
Normal operation
Normal operation
1. Undervoltage U<160 V or
Overvoltage U>253 V
2. Modul overheating: temperatur inside
motor too high
Pump does not restart by itself due to a
permanent failure
1. Pump is not connected to power supply 1. Check cable connection