MASTER LEVEL

The MASTER LEVEL control sets the overall output level of the amplifier and, providing the INPUT
GAIN controls have been correctly set this control should not have to be on a very high setting.
Having the MASTER LEVEL control on a high setting and the INPUT GAIN on a low setting will
only result in unnecessary noise being added to the amplifier and will tend to degrade the signal
purity. Please check that you have adjusted the INPUT GAIN control to its optimum setting.
50/60Hz
VAC
POWER
PIN 1 = GND, PIN 2 = SIG+, PIN 3 = SIG-
SPEAKER
EFFECTS
SHORT OUT TO
'LINK' ACTS AS A
OFF
ON
MUTE REVERB
'LINE IN' AND A
'LINE OUT'
PHASE
SERIAL No:-
IN
OUT
115 V - T 3.15A
REVERB F/S
LINK
SEND
RETURN
PRE EQ D.I.
POST EQ D.I.
230 V - T 1.6A
MANUFACTURED IN ENGLAND BY: TRACE ELLIOT LIMITED
MAINS INPUT 150V.A 115v @ 1.3A
BACK PANEL FACILITIES ( TA50R and TA100R
PHASE SWITCH ( TA100R only )
The TA100R has a speaker PHASE switch located on the rear panel. Switched to its IN PHASE
position this facility has no effect on the sound of the amplifier. However, when switched to OUT
of PHASE it causes phase cancellation to occur at various frequencies that give enhanced clarity
and extra projection to the sound. Phase cancellation also tends to reduce further the chances of
feedback occurring.
REVERB FOOT SWITCH
The REVERB F/S jack socket allows an external footswitch ( not supplied ) to be plugged into the
unit to turn the internal digital effects on and off. The internal effects will be muted when the
switch is shorted.
THE 'LINK' FACILITY
The LINK facility allows two TRACE ACOUSTIC amplifiers to be connected together to operate as
one single larger unit.
To use this simply connect a jack to jack cable from the LINK socket on one unit to the LINK
socket on the other. The preamplifiers in both units will still operate independently but with their
respective MASTER LEVEL controls setting the overall volume from the speakers of both
interconnected units.
All facilities on both preamplifies will operate as normal but the amplified sound will come from
both units. ( e.g. if you plug into either preamplifier, the sound will come from both units: if you
add reverb, this will come from both, etc ).
This LINK socket is configured so that it operates as a LINE OUT as well as a LINE IN connection.
EFFECTS SEND and RETURN
The TRACE ACOUSTIC preamp is provided with a serial effects loop and the sockets for this are
located on the rear panel.
The EFFECTS SEND socket is for linking the preamp sound into your effects unit and the EFFECTS
RETURN socket for returning the signal back to the preamp.
8