the opening. Continue with the connection as described in the
2nd paragraph under B.
● Surface mount wiring from below
On the cover plate [ 1 ], bottom centre, break out the wiring
lead through [ 9 ]. When the mounting plate [ 2 ] has been
attached as shown in fig. C, route the surface mount wiring
through the opening in the cover plate. Continue with the
connection as described in the 2nd paragraph under B.
● Connecting lead with plug.
Connection to a nearby socket with a flexible connecting lead
with plug. On the cover plate [ 1 ], bottom centre, break out the
wiring lead through [ 9 ]. Slide the cover plate into the moun-
ting plate from below. Insert the attached terminal [ 11 ]. Cut
the plug at the connection lead [ 5 ] of the appliance, strip the
cable and, squeeze the wire end ferrules on. Prepare the con-
necting lead with the plug in the same way and route through
the opening in the cover plate. Connect both wires as shown
in fig. C and secure with the enclosed strain relief clamps [ 8
]. Push appliance fully down onto the cover plate and screw in
the 2 enclosed countersunk flat head tapping screws.
The appliances are now operational.
4 Switching options
Operate electronic timer switch on TT 1800 and TTH 1800. The
time delay for TT 1800 is 32 secs. and, for TTH 1800 4 mins.
The appliances will switch off automatically.
TT 1800 E, TTH1800 E, T 500 E
The appliances are operated without touching via infrared proximity
switches.
The switching distance (distance between the underside of the
appliance and hands and/or head) is approx. 15 cm (6 inches) for
the TT 1800 / T 500 E and approx. 40 cm (16 inches) for the TTH
1800 E. The switching sensitivity can be changed by a technician.
5 Safety cut-out sensor
TT 1800 E, TTH 1800 E, T 500 E
The integrated electronics prevent continuous operation if the
infrared proximity switch has been covered, e.g. due to chewing
gum vandalism
TT 1800 / T 500 E-models will switch off after 4 mins and TTH 1800
E models after 10 mins. After the source of interference has been
removed, the dryers are operational again.
24 - GB
Original operatin instructions in German
6 Height adjustment for Starmix hair dryers
The attractive, robust Starmix THH500 / TTHH1800 height adjust-
ment, order no. 19 07 09 makes it possible to adjust the hair dryer
continuously and to the user's heigh t.
This makes drying hair much easier, particularly for children and
wheelchair users.
As an alternative to the height adjustment, two hair dryers can be
mounted at different heights, 40 cms (16 inches) apart (range of the
electronic infrared proximity switch 40 cm (16 inches) max. ).

7 Cleaning and maintenance

Vacuum the air intake grille [ 6 ] at the underside of the appliance
with the crevice nozzle of a vacuum cleaner to remove any lint and
dust, if required. Remove any dirt that is stuck to the grille with a
brush.