  • Page 1 RNC5-ES Homeowners Guide Setting a new standard for energy efficient, clean air homes 511 McCormick Blvd London, Ontario Canada N5W 4C8 519.457.1904 General Info / Tech Support: 69-RNC5-ES-Owners 012616 1.855.247.4200 www.lifebreath.com...
  • Page 2: Table Des Matières

    Homeowner Information Dealer / Contractor Information Dealer_________________________________ Model___________________________________ Serial Number____________________________ Installer________________________________ Telephone/Contact_______________________ Installation Date_________________________ Register your HRV for warranty at www.lifebreath.com For any warranty information, please contact Airia Brands 511 McCormick Blvd. London ON N5W 4C8 T 1-855-247-4200 F 1-800-494-4185...
  • Page 3 Selecting the Ventilation Rate That is Right for You The modes of operation and speeds are used to adjust your indoor ventilation rate. Experiment with the ventilation levels in your home to evaluate the ideal amount of ventilation to suit your home and personal preferences.
  • Page 4: How The Dehumidistat Works

    How the Dehumidistat Works Only the DXPL02, BC02 and BC03 controls are equipped with an adjustable Dehumidistat. High indoor humidity levels, during the heating season, have become a problem in many well insulated, tight homes, excessive condensation on the window is a visual sign of high indoor humidity levels.
  • Page 5: Humidity Control

    The Lifebreath Ventilation Control 99-BC02 The Lifebreath Ventilation Control offers advanced features to control your home's ventilation. Key Features: 2 speed fan setting (LOW / HIGH)  Standby setting (fan OFF)  Humidity Electronic Dehumidistat Setting  Compatible with 99-DET02 Wireless ...
  • Page 6 The Lifebreath Ventilation Control 99-BC03 The Lifebreath Ventilation Control offers advanced features to control your home's ventilation. Key Features: Continuous LOW fan speed operation  Electronic Dehumidistat  Humidity 3 modes of operation:  Setting Ventilation • 20/40 Mode Indicator Recirculation •...
  • Page 7 The Lifebreath Ventilation Control 99-BC04 The Lifebreath Ventilation Control offers advanced features to control your home's ventilation. Key Features: 2 speed fan setting (LOW / HIGH)  Standby setting (fan OFF)  20/40 mode  Compatible with 99-DET02 Wireless  20/40 Mode Timers Indicator Light...
  • Page 8 The Lifebreath Digital Control 99-DXPL02 The Lifebreath Digital Control offers the most advanced features to control your home's ventilation. Key Features : 5 speed fan setting Instruction Card  Standby setting (fan speed 0)  Electronic Dehumidistat  20/40/60 HIGH speed override button ...
  • Page 9: Service Indicator

    Digital Control (continued) Setting the Dehumidistat For a full description of the Dehumidistat function, refer to page 4 "How the Dehumidistat Works". The DXPL02 control displays the current indoor humidity in LARGE numbers and the Dehumidistat setting in SMALL numbers on the screen. If the indoor humidity is above the set point, the DXPL02 control will initiate HIGH Fan speed operation in Ventilation mode until the indoor humidity has been reduced below the set point.
  • Page 10: Replacing The Battery

    Timers (continued) Removable Lifebreath Wireless 20/40/60 Minute Timer Backplate 99-DET02 Initiates high speed ventilation for 20, 40 or 60 minutes. The 20/40/60 minute status lights indicate high speed operation. 20/40/60 Minute Status Lights Wireless Timers have an estimated range of 40' with no obstructions.
  • Page 11: Indicator Led's

    Timers ( continued) Lifebreath Wireless Repeater 99-RX02 The Wireless Repeater is used to extend range of the 99- DET02 Wireless Timers. The Repeater plugs directly into a 120V power outlet. The 99-RX02 wirelessly connects to the main control as well as the 99-DET02 Timers. The 99-RX02 Repeater should be installed at the halfway Power Plug point between the 99-DET02 Wireless Timer and the...
  • Page 12: Maintenance Routine

    Maintenance Routine 1. Inspect Exterior Hoods at Least Once a Month Make sure exhaust and fresh air supply hoods are not blocked or restricted by leaves, grass, or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen).
  • Page 13 Maintenance Routine Continued 4. Motors — Maintenance Free 5. Drain (condensate) Line - Clean Once a Year Inspect drain line, drain spout and “P” trap for blockage, mold or kinks. Flush with warm soapy water and replace if worn, bent or unable to clean. 6.
  • Page 14: Troubleshooting

    Troubleshooting SOLUTION CAUSE SYMPTOM Poor airflows 1/4 in (6 mm) mesh on outside Clean exterior hoods or vents   hood is plugged Remove and clean filter  Filters plugged Remove and clean core   Core obstructed Check and open grilles ...
  • Page 15: Additional Information

    Lifebreath RNC Series Heat Recovery Ventilators carry a Lifetime Warranty on the heat recovery core and a 5 year replacement parts warranty. Register for your warranty: www.lifebreath.com or phone 1-855-247-4200 (toll free) Note: Airia will require the HRV Model and serial number(s) for the registration of your HRV.