9.
TROUBLE SHOOTING
The heater is equipped with an electronic diagnostic system which will detect fault conditions ranging from poor gas
or dc supply to internal heater malfunctions. In the event of a failure, the red light on the control panel will flash a
number of times, pause, and repeat until switched off. Count the number of flashes and refer to the table below.
Lockout Clearing Procedure
Number of
Fault
Flashes / bars lit
1
No Flame Detected
2
Overheat
Low/High Supply
3
Voltage
5
Other / Internal Fault
Solid /
General Fault
all bars lit
Whale Water Heater Control Panel
If the Water Heater lockout condition has been identified by 3 or 5 flashes, the lockout must be cleared by
turning the dc power 'off' and then 'on' again at the master switch in the vehicle. The Water Heater must be in the
'off' position when cycling the dc power. If the first attempt is unsuccessful, you can retry an additional 4 times. If the
lockout still will not clear (identified by a solid LED or all bars lit), please press the red Reset Button on the Water
Heater once (see Fig. 28).
If the Water Heater lockout condition has been identified by 1 or 2 flashes, the lockout must be cleared by pressing
the red Reset Button for 1 to 2 seconds on the Water Heater (see Fig. 28).
If the Water Heater lockout condition has been identified by a solid red LED or all bars lit and / or five or more
unsuccessful attempts to clear a lockout have been made, the lockout must be cleared by pressing the red Reset
Button on the Water Heater once (see Fig. 28).
Drain valve discharge pipe
Remedy
Check gas supply making sure there is gas in the bottle, no blockage in the
gas line and all valves are open. Ensure that if the temperature is below
5°C, only propane gas is used. Clear lockout as described below.
Check that there is water in the appliance. Whale recommends that you wait
at least 5 to 10 minutes to allow the Water Heater to cool before clearing the
lockout as described below.
Minimum operating voltage is 10V dc, maximum is 15V dc, when
measured at the Water Heater. Check battery voltage. If between 10V dc
and 15V dc, check connections between Water Heater and battery. Check
alternator or external battery charging. Clear lockout as described below.
Attempt to clear lockout as described below. If this fails, contact Webasto.
Two faults have occured at the same time OR at least five lockout clearing
attempts have been unsuccessful. Clear lockout by pressing the red Reset
Button on the Water Heater as described below.
Cold water in
Fig. 28 Location of reset button
14
Red reset button
Hot water out