CONNECTING TO AN EXTERNAL FUEL TANK
(BLAZE 600 D TURBO)
Beckett CF800 is fitted with 3/8" SAE male fittings and is set up for a 2 line system to eliminate
priming. Ensure fuel tank has a supply line and a return line and connect the supply line to the 3/8"
SAE fitting on the inlet side of the fuel filter and the return line to the return fitting located on the
Beckett Burner pump. For a 1 line system remove bypass plug located on inlet port of Beckett
Pump and just connect fuel line to inlet side of fuel filter.
ELECTRICAL
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE
120V SUPPLY MUST BE AVAILABLE.
INSTALLATION
10/3 upto 100ft
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.
The electrical grounding of the heater shall be in compliance with the National Electrical Code, ANSI/NFPA
70, or the CSA C22.1, Canadian Electrical Code, Part I
Tel: (905) 793-2525 | Fax: (905) 793-8768 |
1-800-486-4328
1-204-633-1999
ELECTRICAL SYSTEM
Volts-Hertz-Phase
Full Load (Amps) (1PH)
Max fuse size (Amps) (1PH)
with time delay
CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
100 Eagle Drive
Winnipeg, MB Canada
BLAZE
600 D
120-60-1
11.5
15
www.campoequipment.com