BWL-1S-07 outdoor module
Remove the cover, discharge grille and control unit
cover prior to installing the condensate pan heater.
Bild 2
C
A
Aperture for condensate drain pipe
(Please note: Do not obstruct the aperture in the condensate pan)
B
Overflow outlet
Please note: Do not obstruct overflow outlet B.
C
Adhesive cable mounting
Note on 1:
Use cable ties to fix the drain heater.
Note on 2:
Route the heated area of the drain heater as close as possible to apertures A and B on the floor of the condensate
pan.
To do this, fix the drain heater to the floor at three points with adhesive cable mountings.
44