Control unit
M-1000
Control Unit M-1000
The PlymoVent Control Unit, M-1000, is intended for use on systems where seve ral extractors
are connected to one central extraction fan. Together with PlymoVent's Energy Savers, ES-90,
or Automatic Dam pers, ICE-LC, it controls the central fan in a system with a maximum of ten
extractors. As soon as welding starts, a signal is sent from the automatic damper or the energy
saver to the M-1000.
This, in turn, starts the central extraction fan. The fan stops automatically when extraction is
not necessary any longer. To remove residual after-fume, there is an adjustable overrun of
7 sec - 6 min. A two-wire low voltage cable (10-12V) links the electrical control unit with the
automatic dampers/energy savers.
Power supply 115/208/230/460/575 VAC for controlling a central extraction fan (when
using ICE-LC) or a low pressure fan (when using separate fans and ES-90). Relevant motor
overload protection for the central extraction fan is required (not included).
Delivery
The M-1000 is delivered complete and ready for connection.
Advantages
• Reduced operation costs – the central fan is only operational
during arc-time.
• Fully automatic start/stop of the fan when work begins/stops
at any work station.

Technical data

Matning: 230/400 V, 3 ~ (kontaktor för fläkt upp till
4,0 kW är inbyggd). Skall kombineras med relevant
motorskydd (ingår ej).
utgång: 400 volt 3 ~ utgång till fläkten. Fungerar även
för 1 ~ fläktar. Matas då med 230 volt, 1 ~.
automatik: Inställbar efterloppstid 7 sek. - 6 Min.
Installation alternatives
Interlink 12 V
ES
90
Central system: 3 X LM-2 with separate fans and energy savers, connec-
ted to control unit M-1000 for control of the low pressure fan.
0000101014/010313/0 M-1000
Low pressure fan
Control unit M 1000
ES
ES
90
90
TeCHnICal deSCrIPTIon
© Copyright 2008: All rights reserved. All information within this printed matter may not be reproduced,
handed over, copied, xeroxed or translated into another language in any form or means without written
permission from PlymoVent AB. PlymoVent AB reserves the right to make design changes.
• Less noise.
• Stops the fan automatically during breaks and
at the end of the working day.
• Simple installation – low initial cost.
Table for choice of motor overload for M-1000
fan
Motor
FUA-1300
0,37
FUA-1301
0,37
FUA-1800
0,55
FUA-2100
0,75
FUA-2101
0,75
FUA-3000
1,1
FUA-4700
2,2
Central fan
M 1000
Main
fuse
box
Central system: 3 X FM-1520 with automatic dampers ICE-LC,
control unit M-1000 and one central fan FS-3000.
amp
kW v
Prod. no:
3~400 V
0,9
MS-0.9/1.3
1~230 V
3
MS-2.3/3.2
3~400 V
1,3
MS-0.9/1.3
3~400 V
1,75
MS-1.4/2.0
1~230 V
5
MS-4.5/6.3
3~400 V
2,4
MS-2.3/3.2
3~400 V
4,6
MS-4.5/6.3
230 V 1~
Motorised
damper 24V
ICE-LC
Interlink 12 V
M-1000/2/8
EN - 3