Remove the two screws securing the cassette to the pallet

Connections

! IMPORTANT

Chimney connection

The chimney must be sized so as to guarantee the draught declared by the Manufacturer.
Fresh air intake
In a well-insulated house, the air used up by the burning process has to be replaced. This particularly applies to houses with
mechanical ventilation. There are different ways of making sure that an air exchange takes place. The most important thing is to
ensure that there is a supply of air to the room where the wood chimney is located. The external wall vent must be located as close
to the wood chimney as possible, and you must be able to close it when you are not using the wood chimney.
National and local building regulations must be followed with regard to the connection of fresh-air intake.
EMNE:
Closed combustion system
E:
You should use the closed combustion system for the wood-burning chimney if you live in a newly-built, airtight home.
N:
External combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the chimney and the pipe system, which
orking Folder\Designs\Scan 1001\11001900-Manual.iam
can be closed when the oven is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 100 mm ventilation pipe, maximum length: 6 metres with a maximum of 3 bends. We recommend smooth steel pipes.
Mounting of external air supply
To dismount the cover plates for the Ø100 mm sleeve, use an ordinary screwdriver as shown below. Tilt the screwdriver and loosen
the cover plates.
x 6.5 mm
Use and maintenance manual Chronos, Zeus, Ercole e Ermes
The connections must be set up by a technician that is qualified and/or authorised by the
Manufacturer.
27-03-12
N/A
DATO:
VÆGT:
N/A
AREAL:
DK-5492 Vissenbjerg©
External combustion air on
the bottom of the cassette
NAVN:
MATERIALE:
DIMENSION:
C:\Working Folder\Designs\Scan 1001\11001900-Manual.iam
STI:
11001900-Manual
TG.NR:
BC
SIGN:
Scan A/S
EMNE:
VÆGT:
N/A
AREAL:
External air supply on
the rear of the cassette
Rev.1 12/12/2019
Page 67
110019
TG.NR:
27-03-12
N/A
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg©
BC

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

ErmesErcoleZeus

Table des Matières