EMPTYING DATA
bar
psi
Flow rate (l/1')
1.6
23
20
4.2
61
30
8.5
123
40
14.2
2.6
50
FILLING DATA
bar
psi
Flow rate (l/1')
2
30
9
10
145
21
15
217
36
(nozzle #8259552 110°-15 FP)
CONNECTION DIAGRAM (FIG. 4)
Connect as reported in Fig. 4.
USE (FIG. 5-6-7)
All operations should be performed with the mixer
lid closed
Start the pump and:
- Position the ball valve lever with the arrow facing right to
close the connection of the circuit with the tank. (Fig. 5)
- With the lid closed, operate Red tap No. 2, which
activates the tank filling nozzles, and add 5-6 litres of
water. (Fig. 5)
- Open the lid and pour in the product to be mixed in the tank.
- If a container is used for the chemical product, wash it
by turning the container upside down, inserting the can-
wash nozzle, and fully pressing down the valve (Fig. 6),
rinsing out for 30 sec.
- Close the lid and operate Red tap No. 2. Pour in the full
quantity of water required to mix the product.
- Once the desired quantity of mixed product is reached,
operate the ball valve lever which connects the circuit
to the tank (Fig. 7), and the Venturi effect will suck the
entire contents of the mixer.
- Check the emptying of the tank and with the lid closed
operate both taps 1 and 2 in order to wash the tank of
chemical product residues. Wash for 2 min.
PART ONE
Emptying (s)
30
22
16
14
Filling (min)
4.5
2
1.1
I n s t r u c t i o n
MAINTENANCE
Routine maintenance: After every treatment, wash the
inside of the tank and the whole circuit
Extraordinary maintenance: If used intensely, at the end
of the season, carry out a general check of all parts of
the mixer.
Repairs: use only Tecomec spare parts for repairs, and
contact your reseller for assistance
Storage: Store the mixer in places sheltered from
excessive moisture and frost; if subzero temperatures are
possible, add antifreeze liquid for cars.
Scrapping and disposal: the mixer should be disposed of
according to the regulations in force in the country where
the operation is carried out. It is advisable to wash all parts
to remove chemical product residues before disposal.
m a n u a l
6
EN
7