Meter Functions –Audible Continuity (
IMPORTANT: Turn the power OFF on the test circuit
Select the Audible Continuity "
mode button.
Insert:
Black lead in COM terminal.
Ω
-RPM terminal.
Red lead in V-
Connect one test probe to each end of the circuit to be tested.
Circuit complete, the meter will beep continuously.
Circuit open, there is no beep and the display shows to OL (over limit).
Meter Functions –AC or DC Current (A)
IMPORTANT: All current measured flows through the meter.
It is important that you do not:
Measure current greater than 600 Volts AC or DC, with respect to
ground.
Do Not Exceed 30 seconds when measuring continuous current
between 1A-20A. Allow five minutes for cool down before continuing.
Select the "20A" or "mA" range with the rotary switch.
Press the Mode button to select AC or DC.
Insert:
Black lead in COM terminal.
Red lead in the 20A or mA terminal (select 20A if you are unsure of the
current draw).
IMPORTANT: Turn OFF all power to the circuit or disconnect the circuit
from the power source.
Connect:
)
" function with the rotary switch and
Ω
Ω
Ω
Ω