SECTION 4 |
4.2 LAYOUT OF INPUT AND OUTPUT CONNECTIONS
The layout of the various input / output wires is shown in Fig. 4.1 below:
Fig 4.1 Legend:
1. Yellow wire PV +
Connects to the Positive terminal of the Solar Panel
2. Black wire PV -
Connects to the Negative terminal of the Solar Panel
3. Red wire Bat +
Connects to the Positive terminal of the battery through a 10 A fuse
4. Black wire Bat -
Connects to the Negative terminal of the battery
5. White wire Load +
Connects to the Positive terminal of the load (DC lamp) for Night Light Function
6. Black wire Load -
Connects to the Negative terminal of the load (DC lamp) for Night Light Function
7. Blue wire Wet type battery
Is not connected if the battery is sealed type (AGM). Is connected to the Bat – (4) if the battery
is Flooded / Wet Cell type
8. External fuse
32 V, 10 A (preferably within 7" of the battery Positive terminal)
Installation & Operation
Figure 4.1: Layout & Installation Diagram