Installing a 3-wire power cord
WARNING
WARNING
neutral terminal located in the center of the terminal block. The power leads must be connected to the
lower left and the lower right terminals of the terminal block.
1. Remove the 3 lower terminal screws from the
terminal block.
2. Insert the 3 terminal screws through each power
cord terminal ring and into the lower terminals of
the terminal block. Be certain that the center wire
(white/neutral) is connected to the center lower
position of the terminal block.
3. Tighten screws securely into the terminal block. DO
NOT remove the ground strap connection.
4. Go to step 5 on page 10 and proceed with the
installation.
Installing a 4-wire power cord
WARNING
WARNING
located in the lower center of the terminal block. The power leads must be connected to the lower left
and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the
frame of the range with the ground plate and the ground screw.
1. Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3. Insert the one ground screw into the power cord ground wire terminal ring, through the ground
plate, and into the frame of the range.
4. Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the
lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected
to the center lower position of the terminal block. Tighten screws securely into the terminal block.
5. Go to step 5 on page 10 and proceed with the installation.
CAUTION
CAUTION
Live 1 - Neutral
Live 2 - Neutral
Live 1 - Live 2
Manual Installation_30 Oven_SECA_DG68-00109F-09_EN+CFR.indb 7
The neutral or ground wire of the power cord must be connected to the
The neutral wire of the supply circuit must be connected to the neutral terminal
Ground strap
Ground plate
You must check voltage after connecting power cord.
120 V
120 V
208 V / 240 V
Neutral
terminal
Live 1
Black
Black
Live 1
Black
Ground
screw
English - 7
Ground strap
White
Black
Red
Live 2
White
Red
Neutral
White
terminal
Red
Live 2
White
Red
Ground wire
(Green)