Zibro SRE 237 E Mode D'emploi page 63

Masquer les pouces Voir aussi pour SRE 237 E:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
L: A blinking
indica-
tor light is a sign that
you need extra ventila-
tion.
M
Fuel filter
N
back to its lowest position. In the display the number 90 will appear, which
will decline to 10. At the arrival of 10, you will hear an alarm signal every two
minutes, warning you to refill the removable tank. If you do not react, the
heater will extinguish by itself. The heater will also sound a warning signal,
when it switches off. The fuel indicator will blink, while four lines (--:--)
are blinking in the information display. You can stop this by pressing the
button M once more.
Once the heater has used up all its fuel and extinguished, it will take some time, after
the refill, before the heater is completely ready for use again.
L
THE 'VENT' INDICATOR
When there is insufficient ventilation in the room, an intermittent buzzer will be heard
(approximately once each 30 seconds) and the VENT indicator
this signal is given, ensure that the ventilation of the room is improved (e.g. by opening
a door or window a little more), to avoid that the heater shuts off. When the ventila-
tion of the room is improved, the VENT indicator and buzzer will be deactivated. When
there is still insufficient ventilation, the heater shuts off automatically. When this occurs,
e- 1 1 is displayed and the
improving the ventilation of the room (e.g. by opening a door or window a little more),
the heater can be ignited by pushing
M
MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance work. Also
disconnect the plug from the mains. Your Zibro needs hardly any maintenance. It is,
however, important that you clean the air filter 8 and the vent filter 9 with a vacuum
cleaner and the grid 2 with a damp cloth, both on a weekly basis. Remove the air filter
cap occasionally (Fig. M) and clean it with soapy water. Prior to reinstallation, make sure
that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
1
Remove the removable tank 7 from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand.
2
Remove the dirt by tapping the fuel filter upside-down against a hard surface.
(never clean it with water!)
3
Reinstall the fuel filter into the heater.
We recommend that you remove dust and stains in time with a damp cloth, because
otherwise these may cause stains that are hard to remove.
Do not remove any heater components yourself. Always contact your Zibro dealer
for repairs. When the power cord is damaged, it may only be replaced by an autho-
rised fitter. Use a new cord of the type H05 VV-F.
N
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if pos-
sible in its original packaging. Unused fuel cannot be used in the next heating season.
We therefore recommend that you burn up all fuel. If there is still some fuel left, do not
throw it away, but dispose of it in accordance with the local regulations for the disposal
of domestic chemical waste. Always start the new heating season with fresh fuel. When
you start re-using the heater follow the instructions again (starting from section A and
as specified).
indicator is blinking and VENT indicator (
M again.
will be blinking. When
) is lit. After
4
59

Publicité

Table des Matières
loading

Table des Matières