tomatically. This is to prevent the heating
agent inside the radiator from freezing. The
activation of Anti-freeze mode is indicated
by the blinking of the middle diode.
Dryer function
The Dryer turns the device on for 2 hours,
e.g. in order to dry a towel. After this peri-
od of time the device automatically switch-
es to the mode to which it was set before
the dryer mode.
The dryer is turned on by pressing button
(also when the device is off). The device will
start heating at the temperature which was
last set. This temperature can be modified
as required while the device is running (but-
tons
and ). If the device was off before
the dryer mode was been activated, then it
will turn off automatically when the dryer
mode is finished.
Press
button at any time to interrupt the
dryer mode.
Calibrating the temperature span
The standard temperature span of the heat-
ing element is 30-60° C. It is possible to in-
crease or decrease that span by setting
a maximum temperature of between 45° C
and 65° C, (minimum temperature of 30° C
stays unchanged). This allows the user to
achieve a maximum temperature which is
EN
higher than the standard or to effectively
heat a space with the device during lower
surrounding temperatures.
Example: for the temperature regulation
span of up to 45° C (30-45° C) modification
by one step (one diode), means increase/
decrease of temperature by 3.75° C, while
for the temperature regulation span of up
to 65° C (30-65° C) modification by one step
means increase/decrease by 8.75° C.
In order to modify the temperature span,
unplug the device and plug it back in, while
pressing
button. A single diode will start
blinking on the display panel. Use
buttons to set one of the 5 possible maxi-
mum temperatures. The first diode stands
for 45° C. The following diodes refer to the
following maximum temperatures: 50° C,
55° C, 60° C and 65° C.
After selecting the new temperature span
press on/off button to store the new settings.