7. Display

In order for the data generated by the counter to appear in the display, there are various windows containing
designated system information (e.g. energy quantities, water volumes, operating days, water quantities, current
temperatures, maximum values) that can be called up consecutively in loop functions. The energy meter has up to
6 different display loops.
Main loop, due date loop, info loop and month loop.
The month loop consist of up to seven value displays that alternate in a 2-4 s rhythm. For fast visual recognition,
the loops in the display are marked with numbers 1 to 6. The main loop is programmed by default with the current
data, e.g. for energy, volumes, flow rate and the temperatures. The calibrated register is displayed with a padlock
symbol.
Main loop (1)
Sequence
Window 1
1.1
Cumulative energy
1.2
Cumulative volume
1.3
Cumulative cold energy (heat meters with a cold tariff)
1.4
Flow
1.5
Power
Flow line temperature
1.6
Return line temperature *)
1.6b
High-resolution temperature change display (option)
1.7
Differential temperature
1.8
Operating days
1.9
Error status
1.10
Display test
* Without decimal place ** Each with one decimal place
Window 2
Return line temperature **)
Error hours