The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the boiler-stoves?
Smoke outlet that is at least 100 mm in diameter.
An air inlet in the room that is at least 80 cm².
¾" G outlet and inlet fitting.
¾" G drains connection for overpressure valve.
¾" G load fitting.
A certified electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the boiler-stove work without water?
NO. Using the boiler-stove without water will damage it.
3) Do BASIC – ESPRIT - MAGIC - PRESTIGE boiler-stoves emit hot air?
NO. Most of the heat is transferred to the water.
Emit a small amount in the installation environment in the form of radiation from the glass hearth. It is advisable in any case to use a
radiator in the same room.
4) Can I connect the inlet and outlet of the boiler-stove directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do boiler-stoves also supply hot sanitary water?
Hot tap water can be produced using our preassembled KITS.
6) Can I discharge the smoke from the boiler-stoves along the wall?
NO, a discharge which is conform with standards (UNI 10683/05) must reach the ridge of the roof, and in any case proper functioning
requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke forms in the
installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the boiler-stove for combustion. The smoke extractor draws the air from the room into the combu-
stion chamber.
8) What settings are required on the boiler-stove display?
The desired water temperature. The boiler-stove will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the boiler-stove accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) How often do I need to clean the combustion chamber?
Before you ignite the boiler-stove, every time, when it is off and cold. AFTER HAVING BRUSHED THE EXCHANGER PIPES and
moved the smoke duct cleaning rods (see page 37).
10) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the boiler-stove is not used for some time.
11) Can I burn other fuel apart from pellets?
NO. The boiler-stove has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.
12) Can I ignite the boiler-stove by sending an SMS?
Yes, if the DEALER or an electrician has installed the connection via an optional cable code 621240 to the serial port behind the boi-
ler-stove
CLEANING ACCESSORIES (optional extras)
GlassKamin
(code 155240)
Used for cleaning the
ceramic glass
FAQ
41
Ash vacuum cleaner
without motor
(code 275400)
User for cleaning the
hearth

Publicité

Table des Matières
loading

Produits Connexes pour Italiana Camini Adria

Table des Matières