Series Attachment Instructions
The F6 Strip IP can be attached in an end to end formation to create a strip up to 4 meters long from one mounting
point. Do not connect any more than 4 F6 Strip IP products in a row when hanging vertically.
1. Loosen the 3 fastening eye bolts.
2. Slide the connecting bracket out until it stops and tighten the eye bolt closest to the center of the product.
3. If desired, rotate the connecting bracket as desired and tighten the middle eye bolt.
4. Slide the connecting bracket into the second F6 Strip IP and tighten the remaining eye bolt(s).
5. Attach the safety cables as shown in
Install the safety cable last when attaching F6 Strip IP products in series.
F6 Strip IP QRG Rev. 5
QUICK REFERENCE GUIDE
Vertical Mounting
Instructions.
1
2
3
If Desired
4
Alternatively
4