Crest Factor : 1.4 to 2: +0.5%
2 to 2.5: +2%
2.5 to 3: +4%
D.C. current (Ad.c.)
Range
Resolution
300µA
3mA
30mA
300mA
10A
Important : On the 10A range, do not apply currents for measurement of more than 10A for more than 30 seconds.
O
Overload protection : A
l
d
t
ti
Overload protection : 10A input terminal 15A/600V.
Accuracy (97)
0.1 µV
±(1% + 2D)
1µA
±(1.2% + 2D)
10µA
±(1% + 2D)
0.1mA
±(1.2% + 2D)
10mA
±(2% + 2D)
µA/ / A i
mA input terminal 1A/ / 600V
t t
i
l 1A
Crest Factor = Peak value
Accuracy (97RMS)
±(1% + 2D)
±(1.2% + 2D)
±(1% + 2D)
±(1.2% + 2D)
±(2% + 2D)
600V quick-
i k
acting fuse.
ti
f
12
True r.m.s. value.
Voltage drop
200mV (max.)
2V (max.)
200mV (max.)
2V (max.)
2V (max.)
Fuse specification refer to page 22