8000 Series
Art. 8800 - Art. 8800-3
RE-PROGRMMING GUIDE
ENTER THE
ENGINEER'S CODE
Press Enter
(Red light will illu-
minate*)
RE-ENTER THE
ENGINEER'S CODE
Press Enter
ACCESS CODE
Press Enter
ACCESS TIME
Press Enter
YES
Repeat steps for relay 2
***
and relay 3
PRESS ENTER
TWICE TO EXIT
PROGRAMMING
ART. 8800 CONNECTION TERMINALS SIGNALS
SW1 Relay 1 command signal (active low)
SW2 Relay 2 command signal (active low)
NC2 Relay 2 normally closed contact
NO2 Relay 2 normally open contact
C2
Relay 2 common contact
NC1 Relay 1 normally closed contact
NO1 Relay 1 normally open contact
C1
Relay 1 common contact
/
+
12/24Vac/dc power input
/
–
TECHNICAL SPECIFICATIONS
Power requirements:
Power Consumption:
Working Temperature: -10 +50° C
Art. 8800 - Installation instructions
Digital codelock module
Alternatively enter a
new engineer's code
(4 to 8 digits)
Relay code (4-8 dig-
ENTER
its) operate the door
or gate.**
Two digits (01-99
ENTER
sec or 00 for remain
open)
MORE
DOORS?
NO
Max
24Vac/dc
12/24V AC/DC, 2VA
On AC
On DC
Stand-by: 82mA
21.5mA
Operating: 125mA
35.0mA
Engineer's code
Relay 1 code
Relay 2 code
Relay 3 code***
Relay 1 time
Relay 2 time
Relay 3 time***
Notes:
* If the red light does not illuminate, the engineer's code is
incorrect. Follow instructions to return system to preset en-
gineer's factory code.
** On the first loop of the flow chart its relay 1, second loop is
relay 2 and third loop is relay 3.
*** Only for Art. 8800-3
ART. 8800-3 CONNECTION TERMINALS SIGNALS
NO3 Relay 3 normally open contact
C3
Relay 3 common contact
NC2 Relay 2 normally closed contact
NO2 Relay 2 normally open contact
C2
Relay 2 common contact
NC1 Relay 1 normally closed contact
5A
NO1 Relay 1 normally open contact
C1
Relay 1 common contact
/
+
12/24Vac/dc power input
/
–
CLEANING OF THE PLATE
Use a clean and soft cloth. Use moderate warm water or non-ag-
gressive cleansers.
Do not use:
• abrasive liquids;
• chlorine-based liquids;
• metal cleaning products.
- 3 -
Max
24Vac/dc
5A
65801280 - V2.0 - 30/06/18