The instrument is equipped with an external power supply that has no protection against infiltration
of liquids, therefore for its use it is necessary to keep all the electrical cables and connections away
from any liquids and humidity and not to use the appliance in a humid room such as a bathroom or
laundry room.
ATTENTION - Danger of death or serious injury from electric shock.
Contact with live components can lead to injury or death.
Use only the adapter supplied.
Do not put the power supply in contact with liquids nor in a condensing environment, avoid thermal
shock.
All electrical cables and connections must be kept away from moisture or liquids.
Check that all cables and plugs are not damaged, otherwise replace them.
During use, do not cover the power supply and/or do not place it inside boxes
In the event of a loss of power while the appliance is operating, there is no dangerous condition when
the appliance is powered again. In this case, it will be necessary to restart it as it will not restart
automatically.

• Turning on and off, update date, time and language

Connect the instrument to the electricity grid using only the supplied power supply, press
following screens appear on the display:
Device model and software.
Settings for the most important parameters and any info on DHS sensor.
At first use it is advisable to update the date, time and language of the device by performing the following
operations:
Press
key to enter in menu setup.
Press
up to select "
up to select P6.10 Date Setting and confirm with
Press
Use
and
keys to update the "year" value, press
this operation for "day" too; the device automatically updates the date and returns to the setup menu.
Press
, select P6.11 Time Setting and confirm with
to update "hour", "minutes" and "seconds".
key, select P6.13 Select Language and confirm with
Press twice
language and activate it with
To turn off the device press

• Instrument transportation

To move the instrument to a new location, transport it carefully to avoid damage; the instrument can be
damaged if it is not transported correctly. Disconnect the instrument from the power supply and remove all
the connection cables. Remove the electrode arm. To avoid damage to the instrument during long distance
transport, use the original packaging. If the original packaging is no longer available, choose a package that
guarantees safe transport.
UM Serie 880 EN rev.2 30.07.2020
Configuration" and confirm with
.
key in measurement mode.
10
.
.
to confirm and move to "month", repeat
, use
and
keys and confirm with
, move with
key, the
on the desired
EN