DS200 – DS600
Fault
No cooling, absorber
unit warm
Poor cooling
performance
Frost formation in the
refrigerator compart-
ment
No cooling, interior
light flashing
10

Warranty

The statutory warranty period applies. If the product is defective, please contact your
retailer or the manufacturer's branch in your country (see dometic.com/dealer).
For repair and warranty processing, please include the following documents when
you send in the product:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
EN
Possible cause
Refrigerator is not level
Refrigerator was switched on
recently
Cooling unit defective
Refrigerator is exposed to
direct sunlight
Refrigerator door does not
close with a tight seal
Refrigerator was recently
filled
Door of refrigerator does not
close with a tight seal
Refrigerator overloaded
Door not closed properly
No adequate air circulation
for the cooling unit
Refrigerator is not level
Solution
Align refrigerator with water level.
Check cooling again after 5 to
6 hours.
Authorized service agent:
Replace refrigerator.
Take refrigerator out of direct
sunlight.
Check clearances (fig. 5, page 7).
Authorized service agent:
Replace door seal.
Check cooling again after 5 to
6 hours.
Check clearances (fig. 5, page 7)
Authorized service agent:
Replace door seal
➤ Disconnect the device from the
power supply for at least 10 s.
➤ Connect the device
This will reset the electronics and
the device should resume normal
operation.
If the LEDs start flashing again, a
major fault has occurred:
➤ Contact an authorized repair
center.