Heater Specifications

CAUTION: Use only heater oil according to EN 267.
Model
Input Rate*
Fuel Rate
Electrical Input
Line Protection
Pressure Setting
Max. Outlet Temp.
Fuel Tank Capacity
Nozzle Size
Electrical Power Consumption
Air Delivery Rating (Cubic M/Min.)
Fan Rating
Ambient Temp. (Max./Min)
Electric Motor Specifications
Physical Dimensions
Mass
Class
Ignition
Spark Generator
Primary Safety Control

Certification

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
- Service must be performed by a qualified service agency.
DXKH080E
23 kW
2.34 L/hr
230 V, 50 HZ, 1 Ø, 0.89 A
10 A
29 kPa
704° C
22.7 L
0.7 mm
114 W
6 CMM
102 W
-18º C to 60º C
230 V/ 50 Hz/ 200 W/ 2800 RPM/ 6 UF
692 mm x 360 mm x 470 mm
16 kg
1
Direct Spark, Interrupted Ignition
Igniter, 12 kV, 75 mA
Solid State Control
0197
EN-13842
DXKH125E
37 kW
3.66 L/hr
230 V, 50 HZ, 1 Ø, 1.24 A
10 A
47 kPa
704° C
37.9 L
0.9 mm
163 W
13.8 CMM
151 W
-18º C to 60º C
230 V/ 50 Hz/ 250 W/ 2800 RPM/ 6 UF
966 mm x 460 mm x 740 mm
25 kg
1
Direct Spark, Interrupted Ignition
Igniter, 12 kV, 75 mA
Solid State Control
0197
EN-13842
Minimum Clearances:
Outlet: 250 cm / Sides, Top, Rear: 91.4 cm
3
* Input rate is based on the Gross Calorific Heating Value
DXKH180E
53 kW
5.27 L/hr
230 V, 50 HZ, 1 Ø, 1.28 A
10 A
55 kPa
704° C
56.8 L
1.1 mm
182 W
15.5 CMM
170 W
-18º C to 60º C
230 V/ 50 Hz/ 300 W/ 2800 RPM/ 9 UF
1120mm x 480 mm x 745 mm
30 kg
1
Direct Spark, Interrupted Ignition
Igniter, 12 kV, 75 mA
Solid State Control
0197
EN-13842