Setting Up; The Fire Container; The Expansion Valve - Leader GF 42 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. SETTING UP

4.1.

The fire container

4.2.

The expansion valve

WARNING:
The unit will work only with gas in the gaseous state. Always make sure that supply cylinders are
upright; do not place cylinders on their side, as this would mean they release liquid gas, which
would do irremediable damage to the entire gas circuit.
 Place the unit on a flat surface which will not be
damaged by high temperatures.
 Check that there are no inflammable products
in the GF42's area of operation.
 Position the unit so that the remote-control
cable and the gas supply pipe are upwind.
 Place the gas cylinder a good distance from
the fire container; use the entire length of pipe,
with no bends.
 Manually screw the gas expansion valve on
to the cylinder.
 Open the gas cylinder tap completely.
 Do not attempt to start the GF42 below
the 4-position on the expansion valve.
 Do not smoke during these operations.
 There is no solenoid valve to open the gas
supply on this equipment: as soon as the
expansion valve is in position 1, 2 or 3,
the equipment is being supplied and gas will
be coming out of the burners.
 We recommend that you should use industrial
type, 13 kg or 35 kg cylinders of Propane gas
manufactured by Antargaz. To find your local
stockist:
http://www.antargaz.com