Before Installation - NORITZ AMERICA CORPORATION NCC199-SV Manuel D'installation

Chauffe-eau à gaz sans cuve à condensation
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.

Before Installation

Checkup
• Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
Check the Gas
• Check that the rating plate indicates the
correct type of gas.
• Check that the gas supply line is sized for
199,900 Btuh for this unit.
Check the Power
• The power supply required is 120VAC, at 60Hz.
May result in fire or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
• Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
Do Not Use Equipment for Purposes Other Than Those Specified
• Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
• If the water supply is in excess of 12 grains per gallon (200 mg/L) of hardness, acidic or otherwise
impure, treat the water with approved methods in order to ensure full warranty coverage.
4
DANGER
WARNING
NCC199-SV
199,900 BTU
10.3a-2007
4.3a-2007
CAUTION
11,000 BTU
222
840
4.0
10.5
0.85
3.05
15
150
4
199,900
192,700
186,000
186 000
179,300
179 300
3.6
3.6
3.05
3.05

Publicité