Svenska ________________________________ 5 Deutsch _______________________________ 21 Dansk _________________________________37 English _______________________________ 54 Suomi _________________________________ 71 Français ______________________________ 89 Nederlands __________________________105 Norsk ________________________________ 121 Declaration of Conformity ____________137...
Svenska Installations- och skötselanvisning CTC Converter VIKTIGT LÄS NOGGRANT INNAN ANVÄNDNING BEHÅLL FÖR FRAMTIDA BRUK...
Page 6
Svenska Innehållsförteckning Version 3 och 4 ______________________________________________________ En eller 3 kommunikationsplintar __________________________ Leveransomfattning ______________________________________________ Installation ____________________________________________________________ CTC EcoLogic och CTC EcoZenith i550 med en kommunikationsplint _________________________________________ CTC EcoZenith i550 / CTC Ecologic EXT med 3 st. kommunikationsplintar _______________________________ CTC EcoEl V3 __________________________________________________ Inställningar ________________________________________________________ Inställning av värmepump version 4 ____________________ CTC EcoLogic och CTC EcoZenith i550 med en...
7250-1222-0172 584890001 CTC EcoZenith I 550 BBR 7250-1222-0172 584893001 CTC EcoZenith I 550 1x230V I det senare utförandet behövs det en CTC Converter till varje värmepump av version 4. Version 3 och 4 CTC Converter ”översätter” styrningen från Version 3 (V3) till värmepump version 4 (V4). Version 3 (V3) Gemensamt för version 3 (V3) är att dessa har styrning med ”OK”-knapp.
1 st isolerslang Ø10 mm 4 st förskruvningar CTC EcoEl V3 1 st matningskabel för CTC EcoEl V3, 2,5 m 1.L1 2.Com Som kommunikationskabel till CTC EcoAir400 och EcoPart 400 skall LiYCY (TP) användas. LiYCY (TP) är en 4-ledare med skärm, där kommunikationsbärande ledare är tvinnade. CTC Converter...
Om detta inte ON = Terminerad OFF = Ej terminerad efterföljs finns risk för allvarlig skada på Vidrör inte kretskortets komponenter. Kretskortet värmepumpen! kan skadas av statisk uppladdning 3.1 CTC EcoLogic och CTC EcoZenith i550 med en kommunikationsplint Elcentral Brun Värmepump Grön Bygling CTC EcoLogic V3 CTC EcoLogic EXT...
A1. I de konfigurationer som har mer än en värmepump av version 4 måste denna ställas in som A2 respektive A3. CTC EcoPart XL består av 2 st värmepumpar som är från fabrik inställda: • Den översta A2 •...
Page 13
Svenska Alternativ 2 CTC EcoLogic och tidig CTC EcoZenith Endast CTC EcoLogic CTC Converter Värmepump MiniEl Inställd: F2 Version 3 Version 3 A1 = Visar typ Inställd: A3 A2 = Visar typ A3 = 0 Ej använd Värmepump Värmepump OBS: Endast värmepumpen som...
Svenska 4.3 Möjliga konfi gurationer i det senare utförandet av CTC EcoZenith Alternativ 1 Senare CTC EcoZenith CTC Converter Värmepump Värmepump Inställd: F1 Version 3 Version 3 A1 = Visar typ Inställd: A Inställd: A Värmepump Version 4 Inställd: A1 (Fabriksinställning) OBS: Värmepumpen skall...
Version 4 Version 4 Inställd: A1 (Fabriksinställning) Inställd: A1 (Fabriksinställning) Inställd: A1 (Fabriksinställning) OBS: Värmepumparna skall ställas i läge terminerad 4.4 Möjliga konfi gurationer CTC EcoEl CTC EcoEl CTC Converter Inställd: F1 A1 = Visar typ Värmepump OBS: Värmepumpen skall Version 4 ställas i läge terminerad...
Med pilarna kan man öka/minska det visade värdet. 0 = Värmepumpen urkopplad, används ej. Se: Not 1. Ökas värdet visas ”-” tills CTC Converter har läst in typen från värmepumpen 1 = Värmepumpen är av typ EcoPart 2 = Värmepumpen är av typ EcoAir Vid tryck på...
åtgärd. Givare hetgas Givare suggas Givare högtryck Givare lågtryck Endast CTC EcoAir. Detta larm visas när det är fel på 4-vägsventilen, 4-vägsventil eller så har framledning och retur förväxlats. Text visas vid fel på expansionsventilstyrningen. EVO Motor EVO Off Motorskydd kompressor Hög ström har detekterats till kompressorn.
Text visas vid hög förångningstemperatur expansionsventil. Vid återkommande fel, kontakta din installatör. Låg överhettning expv. Text visas vid låg överhettningstemperatur expansionsventil. Vid återkommande fel, kontakta din installatör. Text visas då CTC Converter ej kan kommunicera med värmepump/ar Kommunikationsfel mellan CTC Converter och värmepump Kommunikationsfel mellan Text visas då...
Deutsch Deutsch Installations- und Wartungsanleitung CTC Converter WICHTIGER HINWEIS VOR DER VERWENDUNG SORGFÄLTIG LESEN FÜR SPÄTEREN GEBRAUCH AUFBEWAHREN CTC Converter...
Page 22
_______________________________________________ CTC EcoZenith ______________________________________________ Einstellungen _____________________________________________________ Konfi guration der Wärmepumpe Version 4 _________ CTC EcoLogic und CTC EcoZenith i550 mit einer Kommunikations-Klemmenleiste ______________________ Mögliche Konfi gurationen der aktuelleren Version von CTC EcoZenith ________________________________________ Mögliche Konfi gurationen von CTC EcoEl __________...
Page 23
Deutsch Allgemeines Mit der Version 4 des CTC Converter können Wärmepumpen an die Version 3 (V3) der Produkte CTC EcoEl, CTC EcoLogic, CTC EcoLogic EXT and CTC EcoZenith i550 angeschlossen werden. Wärmepumpen Version 4 (V4) CTC EcoAir 406 CTC EcoPart 406 CTC EcoAir 408 CTC EcoPart 408 CTC EcoAir 410 CTC EcoPart 410 CTC EcoAir 412 CTC EcoPart 412 CTC EcoAir 415* CTC EcoPart 414* CTC EcoAir 420* CTC EcoPart 417* CTC EcoPart 425* Beachtung: CTC EcoPart 430* CTC EcoPart 435* * Nicht für CTC EcoEl V3...
Wärmepumpe und Steuerung müssen immer getrennt mit Strom versorgt werden. CTC EcoZenith I 550 Die CTC EcoZenith Version 3 gibt in zwei verschiedenen Ausführungen, einer älteren Ausführung mit nur einem Kommunikationsanschluss, sowie einer neueren Ausführung mit drei Anschlüssen für die Kommunikation. Die Seriennummer der neueren Ausführungen beginnen mit:...
1 x Steuerungseinheit (H x B x T) 18 x 18 x 7 cm 3 x Isoliermanschetten Ø 8 mm 1 x Isoliermanschette Ø 10 mm 4 x Kabelverschraubungen CTC EcoEl V3 1 x Versorgungskabel für CTC EcoEl V3, 2,5 m 1.L1 2.Com Verwenden Sie LiYCY (TP) als Kommunikationskabel zu EcoPart 400.
Strom versorgt werden. • Die Kabel an die zwei Verbindungsblöcke anschließen. Die Ladepumpe wird von der • Sicherstellen, dass die Terminierungsschleife im Converter in der CTC EcoAir 400 terminierten Position (ON) ist. mit Strom versorgt, siehe Bedienungs- anleitung zu EcoAir 400.
Das System kann bis zu drei Wärmepumpen beinhalten. 4.1 Konfi guration der Wärmepumpe Version 4 Wärmepumpen Version 4 (CTC EcoPart 400und CTC EcoAir 400) sind fabrikseitig auf A1 eingestellt. In Systeme mit mehreren Wärmepumpen Version 4 müssen die beiden letzteren auf A2 und A3 eingestellt werden.
Page 30
Deutsch Alternative 2 CTC EcoLogic und aktuellere CTC EcoZenith Nur CTC EcoLogic CTC Converter Wärmepumpe MiniEl Einstellung: F2 Version 3 Version 3 A1 = Zeigt Typ Einstellung: A3 A2 = Zeigt Typ A3 = 0 Nicht in Benutzung Wärmepumpe Wärmepumpe...
Deutsch 4.3 Mögliche Konfi gurationen der aktuelleren Version von CTC EcoZenith Alternative 1 Aktuellere CTC EcoZenith CTC Converter Wärmepumpe Wärmepumpe Einstellung: F1 Version 3 Version 3 A1 = Zeigt Typ Einstellung: A Einstellung: A Wärmepumpe Version 4 Einstellung: A1 (fabrikseitig) Zur Beachtung: Die Wär-...
Einstellung: A1 (fabrikseitig) Einstellung: A1 (fabrikseitig) Einstellung: A1 (fabrikseitig) Zur Beachtung: Die Wär- mepumpen müssen in der terminierten Position sein. 4.4 Mögliche Konfi gurationen von CTC EcoEl CTC EcoEl CTC Converter Einstellung: F1 A1 = Zeigt Typ Wärmepumpe Zur Beachtung: Die Wär-...
Mit den Pfeiltasten können Sie den angezeigten Wert erhöhen/senken. 0 = Wärmepumpe nicht verbunden, nicht in Benutzung Siehe: Anmerkung 1 Wird der Wert erhöht, erscheint im Display "-" bist der CTC Converter den Typ aus der Wärmepumpe eingelesen hat. 1 = Die Wärmepumpe ist eine EcoPart 2 = Die Wärmepumpe ist eine EcoAir...
Sie, ob er erneut auftaucht. Prüfen Sie außerdem den installierten Solefilter. Tritt dieser Fehler wiederholt auf, setzen Sie sich mit dem Installateur in Verbindung. Die Kombination aus CTC Converter und CTC EcoPart 400 kann einen Alarm auslösen. Durch Austausch von Sensor Sole Zulauf / Sole Ablauf beheben Niedrige Soletemp.
Diese Meldung wird angezeigt, wenn die Überhitzungstemperatur des Niedr. Überhitz. Exp. Expansionsventils niedrig ist. Tritt dieser Fehler auf, setzen Sie sich mit dem Ventil Installateur in Verbindung. Diese Meldung wird angezeigt, wenn der CTC Converter nicht mit der/den Kommunikationsfehler zwischen CTC Wärmepumpe/n kommunizieren kann. Converter und Wärmepumpe...
Dansk Dansk Installations- og vedligeholdelsesvejledning CTC Converter VIGTIGT SKAL LÆSES OMHYGGELIGT FØR BRUG SKAL OPBEVARES TIL FREMTIDIG REFERENCE CTC Converter...
Page 38
Konfi guration af varmepumpe version 4 _____________ CTC EcoLogic og CTC EcoZenith i550 med én kommunikationsklem- række __________________________________________________________ Mulige konfi gurationer af den senere version af CTC EcoZenith ______________________________________________ Mulige konfi gurationer af CTC EcoEl _________________ Funktioner __________________________________________________________ Generelt _______________________________________________________ Display _________________________________________________________ Knapper og indstillinger...
Page 39
CTC EcoPart 430* CTC EcoPart 435* * Ikke til CTC EcoEl V3 Placering Styreenheden skal monteres på en væg indendørs ved siden af CTC EcoEl, CTC EcoLogic eller CTC EcoZenith. Sikkerhed Installationen skal foretages af en autoriseret installatør. Dette udstyr er ikke beregnet til brug af personer (herunder børn) med nedsatte fysiske, sensoriske eller mentale evner eller manglende erfaring og viden, medmindre de er under overvågning eller har fået instruktioner...
Varmepumpen og styringen skal altid have separat strømforsyning. CTC EcoZenith I 550 CTC EcoZenith version 3 fås i to forskellige udførelser. En tidligere version med kun én kommunikationsport og en senere version med tre kommunikationsporte. Den senere version har serienumre, som starter med:...
1 x styreenhed (H x B x D) 18 x 18 x 7 cm 3 x isolationsovertræk Ø8 mm 1 x isolationsovertræk Ø10 mm 4 x kabelpakninger CTC EcoEl V3 1 x forsyningskabel til CTC EcoEl V3, 2,5 m 1.L1 2.Com Som kommunikationskabel til EcoPart 400 skal du bruge LiYCY (TP), som er et afskærmet 4-lederkabel, hvor de kommunikationsbærende ledere er snoede.
Fjern 18 cm af kappen fra kablerne. Klip kabelskærmen af (skal tilsluttes en varmepumpe). • Sæt de forskellige kabler ind i isolationsovertrækket. BEMÆRK! Ladepumpen til CTC EcoAir 400 må ikke strømforsynes fra kedlen (EcoEl • Tilslut kablerne til de to forbindelsesklemmer. v3, Ecologic v3 og EcoZenith l550 v3).
Dansk 3.4 CTC EcoLogic CTC EcoLogic A2 com ---------- Konverterklemme 4 N ----------------- Konverterklemme 5 3.5 CTC EcoZenith Tidligere version Konverterklemme 4 Konverterklemme 5 N-klemme Senere version Konverterklemme 4 com 1 Konverterklemme 5 Konverterklemme 4 com 2 Konverterklemme 5 Konverterklemme 4...
4.1 Konfi guration af varmepumpe version 4 Varmepumper i version 4 (CTC EcoPart 400 og CTC EcoAir 400) er fabriksindstillede til A1. I systemer med mere end én varmepumpe i version 4 skal de sidste indstilles til henholdsvis A2 og A3.
Page 46
Dansk Alternativ 2 CTC EcoLogic og den tidlige version af CTC EcoZenith Kun CTC EcoLogic CTC Converter Varmepumpe MiniEl Indstilling: F2 Version 3 Version 3 A1 = viser type Indstilling: A3 A2 = viser type A3 = 0 ikke i brug...
Dansk 4.3 Mulige konfi gurationer af den senere version af CTC EcoZenith Alternativ 1 Senere version af CTC EcoZenith CTC Converter Varmepumpe Varmepumpe Indstilling: F1 Version 3 Version 3 A1 = viser type Indstilling: A Indstilling: A Varmepumpe Version 4 Indstilling: A1 (fabriksindstilling)
Version 4 Indstilling: A1 (fabriksindstilling) Indstilling: A1 (fabriksindstilling) Indstilling: A1 (fabriksindstilling) OBS! Varmepumperne skal indstilles til den terminerede position. 4.4 Mulige konfi gurationer af CTC EcoEl CTC EcoEl CTC Converter Indstilling: F1 A1 = viser type Varmepumpe OBS! Varmepumpen skal...
Du kan øge/mindske den viste værdi med pileknapperne. 0 = varmepumpe frakoblet; ikke i brug. Se Note 1. Hvis værdien øges, vises " - ", indtil CTC Converter har indlæst typen fra varmepumpen. 1 = varmepumpen er en EcoPart 2 = varmepumpen er en EcoAir Ved at trykke på...
Føler hedgas andre følere. Føler sugegas Føler højtryk Føler lavtryk Kun CTC EcoAir. Denne alarm vises, når der er en fejl med 4-vejsventil 4-vejsventilen, eller når returløbet og det primære fremløb er blevet omskiftet. EVO-motor Denne alarm vises, når der er en fejl i ekspansionsventilstyringen.
Lav overhed. ekspv. overhedningstemperatur er lav. Hvis denne fejl optræder, skal du kontakte installatøren. Kommunikationsfejl Denne meddelelse vises, når CTC Converter ikke kan kommunikere med varmepumpen/varmepumperne. mellem CTC Converter og varmepumpen. Denne meddelelse vises, når CTC Converter ikke kan kommunikere med Kommunikationsfejl EcoEl/EcoLogic/EcoZenith.
English English Installation- and maintenance instructions CTC Converter IMPORTANT READ CAREFULLY BEFORE USE KEEP FOR FUTURE REFERENCE CTC Converter...
Page 55
Confi guration of heat pump version 4 _________________ CTC EcoLogic and CTC EcoZenith i550 with one communication termi- nal block _________________________________________________________ Possible confi gurations of the later version of the CTC EcoZenith ________________________________________________ Possible confi gurations of CTC EcoEl _________________ Functions _____________________________________________________________ General ___________________________________________________________ Display ____________________________________________________________ Buttons and settings...
Page 56
CTC EcoPart 430* CTC EcoPart 435* * Not for CTC EcoEl V3 Placement The control unit must be wall mounted indoors next to CTC EcoEl, CTC EcoLogic or CTC EcoZenith. Safety Installation must be performed by an authorised installation engineer. This appliance is not intended for use by persons ( including children ) with...
7250-1222-0172 584890001 CTC EcoZenith I 550 BBR 7250-1222-0172 584893001 CTC EcoZenith I 550 1x230V For the later variant a CTC Converter is needed for each version 4 heat pump. Version 3 and 4 The CTC Converter "translates" the control from Version 3 (V3) to the heat pump version 4 (V4). Version 3 (V3) Common to version 3 (V3) is that they have a control with an "OK" button.
(H x W x D) 18 x 18 x 7 cm 3 x Insulation sleeves Ø8 mm 1 x Insulation sleeve Ø10 mm 4 x cable glands CTC EcoEl V3 1 x supply cable for the CTC EcoEl V3, 2.5 m 1.L1 2.Com...
• Connect the cables to the two connection blocks. the boiler (EcoEl v3, Ecologic v3 and • Check that the termination loop in the Converter is in the terminated EcoZenith I550 v3). position (ON). The charge pump must be operated/...
Remove the CTC EcoZenith i550 / loop (N to 5)! CTC Ecologic EXT with 3 x communication terminal blocks CTC Converter 3.3 CTC EcoEl V3 The power supply cable is supplied with the CTC Converter for the CTC EcoEl V3 to CTC Converter. CTC EcoEl V3 Brown 1.L1 Loop White Heatpump Green 2.Com...
English 3.4 CTC EcoLogic CTC EcoLogic A2 com ---------- Converter terminal 4 N ----------------- Converter terminal 5 3.5 CTC EcoZenith Earlier version Converter terminal 4 Converter terminal 5 N terminal Later version Converter terminal 4 com 1 Converter terminal 5...
4.1 Confi guration of heat pump version 4 Version 4 heat pumps (CTC EcoPart 400 and CTC EcoAir 400) are factory set to A1. In systems containing more than one version 4 heat pump, the latter must be set to A2 and A3, respectively.
Page 63
English Alternative 2 CTC EcoLogic and early CTC EcoZenith CTC EcoLogic only CTC Converter Heat pump MiniEl Set: F2 Version 3 Version 3 A1 = Shows type Set: A3 A2 = Shows type A3 = 0 Not in use Heat pump Heat pump N.B.
English 4.3 Possible confi gurations of the later version of the CTC EcoZenith Alternative 1 Later CTC EcoZenith CTC Converter Heat pump Heat pump Set: F1 Version 3 Version 3 A1 = Shows type Set: A Set: A Heat pump Version 4 Set: A1 (Factory set) N.B.
Set: A1 (Factory set) Set: A1 (Factory set) Set: A1 (Factory set) N.B. The heat pumps must be set to the terminated position 4.4 Possible confi gurations of CTC EcoEl CTC EcoEl CTC Converter Set: F1 A1 = Shows type Heat pump N.B.
Using the arrow buttons, you can increase/reduce the indicated value. 0 = Heat pump disconnected; not used. See: Note 1. If the value is increased, “-” is displayed until the CTC Converter has read in in the type from the heat pump...
Check also the brine pump speed. Press reset and check whether the alarm recurs. Also check the brine filter that has been installed. If the error recurs, contact your installer. CTC Converter and CTC EcoPart 400 in combination can cause alarm. Fix by replace sensor brine in / brine out Incoming brine temperatures from borehole/ground circuits are too low.
If the error occurs, contact your installer. Low superheat exp. valve This message appears when the expansion valve's superheat temperature is low. If the error occurs, contact your installer. This message appears when CTC Converter cannot communicate with Communication error between CTC Converter heat pump/s...
Versio 4 (V4) Yhteistä version V4 kanssa on, että niissä ohjaus tapahtuu näytöltä. Katso kuva 2 oikealla. Näitä lämpöpumppuja ovat: CTC EcoAir 406, 408, 410, 415, 420 ja CTC EcoPart 406, 408, 410, 412, 414, 417, Kuva 2. V4-näyttö Yksi tai kolme tiedonsiirtoliitäntää...
ON = Liitetty OFF = Ei liitetty täytyy ottaa suoraan EcoAirista. Katso ohje Älä kosketa piirikortin osia. Staattinen varaus voi käyttöohjekirjasta. vahingoittaa piirikorttia. 3.1 CTC EcoLogic ja CTC EcoZenith i550 yhdellä tiedonsiirtoliitännällä Sähkökeskuk- sesta Ruskea Valkoinen Lämpöpumppu Vihreä...
Järjestelmässä voi olla enintään 3 lämpöpumppua. 4.1 Version 4 lämpöpumpun asetukset Version 4 lämpöpumput (CTC EcoPart 400 ja CTC EcoAir 400) toimitetaan asetettuina kuten A1. Asetuksissa, joissa version 4 lämpöpumppuja on useampi kuin yksi, tämä on asetettava kuten A2 tai A3.
Page 82
Suomi Vaihtoehto 2 CTC EcoLogic ja aiempi CTC EcoZenith Vain CTC EcoLogic CTC Converter Lämpöpumppu MiniEl Asetettu: F2 Versio 3 Versio 3 A1 = Näyttää tyypin Asetettu: A3 A2 = Näyttää tyypin A3 = 0 Ei käytössä Lämpöpumppu Lämpöpumppu HUOM: Vain lämpöpumppu, joka...
Suomi 4.3 Mahdolliset kokoonpanot CTC EcoZenithin myöhemmässä versiossa Vaihtoehto 1 Myöhempi CTC EcoZenith CTC Converter Lämpöpumppu Lämpöpumppu Asetettu: F1 Versio 3 Versio 3 A1 = Näyttää tyypin Asetettu: A Asetettu: A Lämpöpumppu Versio 4 Asetettu: A1 (Tehdasasetukset) HUOM: Lämpöpumppu on oltava kytketty-tilassa Vaihtoehto 2 Myöhempi CTC EcoZenith...
Versio 4 Versio 4 Versio 4 Asetettu: A1 (Tehdasasetukset) Asetettu: A1 (Tehdasasetukset) Asetettu: A1 (Tehdasasetukset) HUOM: Lämpöpumppujen on oltava kytketty-tilassa 4.4 Mahdolliset kokoonpanot CTC EcoEl CTC EcoEl CTC Converter Asetettu: F1 A1 = Näyttää tyypin Lämpöpumppu HUOM: Lämpöpumppu Versio 4...
OK yli 3 sekuntia valitsee näytössä olevan lämpöpumpun. Näytön arvoa voidaan kasvattaa/pienentää nuolinäppäimillä. 0 = Lämpöpumppu on kytketty pois käytöstä. Katso: Huomautus 1. Jos arvoa kasvatetaan, näytössä on ”-” kunnes CTC Converter on lukenut tyypin lämpöpumpusta 1 = Lämpöpumppu on tyyppiä EcoPart 2 = Lämpöpumppu on tyyppiä...
Anturi imukaasu Anturi korkeapaine Anturi matalapaine 4-tieventtiili Vain CTC EcoAir. Tämä hälytys näkyy, kun 4-tieventtiilissä on vikaa, tai jos lähtö- ja tuloliitännät ovat vaihtuneet. Teksti näkyy, kun paisuntaventtiilin ohjauksessa tapahtuu virhe EVO-moottori EVO pois Kompressoriin on havaittu tulevan korkea virtaus. Paina Moottorinsuoja kuittauspainiketta ja seuraa, laukeaako hälytys uudelleen.
Jos vika toistuu, ota yhteys asentajaan. paisuntaventtiili Matala tulistuslämpötila Teksti näkyy, kun paisuntaventtiilin tulistuslämpötila on matala. paisuntaventtiili Jos vika toistuu, ota yhteys asentajaan. Teksti näkyy, kun CTC Converter ei pysty kommunikoimaan lämpöpumpun Tiedonsiirtovirhe / -pumppujen kanssa CTC Converterin ja lämpöpumpun välillä Tiedonsiirtovirhe CTC Teksti näkyy, kun CTC Converter ei pysty kommunikoimaan EcoEl/...
Français Français Consignes d’installation et de maintenance CTC Converter IMPORTANT LIRE ATTENTIVEMENT AVANT UTILISATION CONSERVER POUR RÉFÉRENCE ULTÉRIEURE CTC Converter...
Page 90
Confi guration d'une pompe à chaleur version 4 CTC EcoLogic et CTC EcoZenith i550 avec un bor- nier de connexion de communication ________________ Confi gurations possible de la version récente de CTC EcoZenith ______________________________________________ Confi gurations possibles de la CTC EcoEI ________ Fonctions _________________________________________________________ Généralités __________________________________________________ Affi chage _____________________________________________________ Boutons et réglages...
Pour la dernière variante, un CTC Converter est nécessaire pour chaque pompe à chaleur version 4. Version 3 et 4 Le CTC Converter « traduit » la commande de la version 3 (V3) pour la pompe à chaleur version 4 (V4). Version 3 (V3) Un point commun avec la version 3 (V3), est la commande avec un bouton «...
(H x l x p) 18 x 18 x 7 cm 3 x gaines isolantes Ø 8 mm 1 x gaines isolantes Ø 10 mm 4 x goupilles de câble CTC EcoEl V3 1 x câble d'alimentation pour la CTC EcoEl V3, 2,5 m 1.L1 2.Com...
à chaleur circuits imprimés. La carte de circuits imprimés pourrait subir des risquerait d'être endommagée par une décharge dégâts graves ! d'électricité statique. 3.1 CTC EcoLogic et CTC EcoZenith i550 avec un bornier de connexion de communication Du boîtier de distribution Marron Pompe à...
/ CTC Ecologic EXT avec 3 x borniers (N à 5) ! de connexion de communication CTC Converter 3.3 CTC EcoEl V3 Le câble d'alimentation électrique est fourni avec le CTC Converter pour la CTC EcoEl V3 au CTC Converter. CTC EcoEl V3 Marron Pompe à 1.L1 Blanc chaleur CTC...
4.1 Confi guration d'une pompe à chaleur version 4 Les pompes à chaleur version 4 (CTC EcoPart 400 et CTC EcoAir 400) sont paramétrées en usine sur A1. Dans les systèmes contenant plus d'une pompe à chaleur version 4, les plus récentes doivent être paramétrées, respectivement, sur A2 et A3.
Page 98
Français Alternative 2 CTC EcoLogic et version ancienne de CTC EcoZenith CTC EcoLogic uniquement CTC Converter Pompe à chaleur MiniEl Régler : F2 Version 3 Version 3 A1 = Afficher le type Régler : A3 A2 = Afficher le type A3 = 0 Non utilisé...
Français 4.3 Confi gurations possible de la version récente de CTC EcoZenith Alternative 1 CTC EcoZenith récente CTC Converter Pompe à chaleur Pompe à chaleur Régler : F1 Version 3 Version 3 A1 = Afficher le type Régler : A Régler : A Pompe à chaleur Version 4 Régler : A1 (réglage usine)
Régler : A1 (réglage usine) Régler : A1 (réglage usine) NB : Les pompes à chaleur doivent être paramétrées sur la position fermée. 4.4 Confi gurations possibles de la CTC EcoEI CTC EcoEl CTC Converter Régler : F1 A1 = Afficher le type Pompe à chaleur NB : La pompe à...
Les touches fléchées permettent d'augmenter ou de réduire la valeur affichée. 0 = pompe à chaleur déconnectée ; non utilisée. Voir : Note 1. Si vous augmentez la valeur, « - » s'affiche jusqu'à ce que le CTC Converter ait relevé le type de la pompe à chaleur.
Français 5.4 Menus 1 = CTC EcoPart 400 OK > 3 s 2 = CTC EcoAir 400 OK < 3 s 1 = CTC EcoPart 400 OK > 3 s OK > 3 s 2 = CTC EcoAir 400 1 = CTC EcoPart 400 OK >...
Contrôlez également le filtre du capteur qui a été installé. Si l'erreur réapparaît, contactez votre installateur. La combinaison du convertisseur CTC et de CTC EcoPart 400 peut causer une alarme. Réparez en remplaçant le capteur Eau glyc en/sor. Les températures de l'eau glycolée entrant depuis les circuits de forage/sol Temp.
Ce message apparait lorsque la température de surchauffe de détendeur Bas Surchauffe Détend. est basse. Si l'erreur se produit, contactez votre installateur. Ce message apparaît lorsque le CTC Converter ne peut pas communiquer Erreur de avec la ou les pompes à chaleur.
Nederlands Nederlands Installatie- en onderhoudsinstructies CTC Converter BELANGRIJK VOOR GEBRUIK ZORGVULDIG LEZEN BEWAREN OM LATER IN TE KIJKEN CTC Converter...
Page 106
Confi guratie van warmtepomp versie 4 _____________ CTC EcoLogic en CTC EcoZenith i550 met een communicatie-klemmenstrook ________________________ Mogelijke confi guraties van de latere versie van de CTC EcoZenith _____________________________________________ Mogelijke confi guraties van de CTC EcoEl ________ Functies ____________________________________________________________ Algemeen ____________________________________________________ Scherm _______________________________________________________...
Page 107
* Niet voor CTC EcoEl V3 Plaatsing De besturingseenheid moet binnenshuis aan de wand worden gemonteerd naast de CTC EcoEl, de CTC EcoLogic of de CTC EcoZenith. Veiligheid De installatie moet worden uitgevoerd door een erkende installatietechnicus. Deze is niet bedoeld voor gebruik door personen (waaronder kinderen) met...
7250-1222-0172 584890001 CTC EcoZenith I 550 BBR 7250-1222-0172 584893001 CTC EcoZenith I 550 1x230V Voor de latere variant is een CTC Converter nodig voor iedere warmtepomp versie 4. Versie 3 en 4 De CTC Converter "vertaalt" de aansturing van Versie 3 (V3) naar de warmtepomp versie 4 (V4). Versie 3 (V3) Gemeenschappelijk bij versie 3 (V3) is dat ze een regeling hebben met een "OK"-knop.
1 x besturingseenheid (H x B x D) 18 x 18 x 7 cm 3 x isolatieslangen Ø8 mm 1 x isolatieslangen Ø10 mm 4 x kabelwartels CTC EcoEl V3 1 x voedingskabel voor de CTC EcoEl V3, 2,5 m 1.L1 2.Com Gebruik een LiYCY (TP) com-kabel naar de EcoPart 400.
Raak de componenten van de printplaat niet aan. wordt genomen, kan De printplaat kan worden beschadigd door statische er ernstige schade ontlading ontstaan aan de warmtepomp! 3.1 CTC EcoLogic en CTC EcoZenith i550 met een communicatie-klemmenstrook Van verdeelkast Bruin Warmtepomp Groen De lus...
CTC EcoZenith i550, lus (N naar 5)! CTC EcoLogic EXT met 3 x communicatie- klemmenstroken CTC Converter 3.3 CTC EcoEl V3 Bij de CTC Converter wordt een voedingskabel meegeleverd voor de CTC EcoEl V3 naar CTC Converter. CTC EcoEl V3 Bruin 1.L1 Warmtepomp Groen De lus 2.Com...
A1. In systemen met meer dan één warmtepomp versie 4, moeten de volgende worden ingesteld op respectievelijk A2 en A3. De CTC EcoPart XL bestaat uit 2 warmtepompen die in de fabriek zijn ingesteld op: • De bovenste A2 •...
Page 114
Nederlands Mogelijkheid 2 CTC EcoLogic en eerdere CTC EcoZenith Alleen CTC EcoLogic CTC Converter Warmtepomp MiniEl Instellen: F2 Versie 3 Versie 3 A1 = Geeft type weer Instellen: A3 A2 = Geeft type weer A3 = 0 Niet in gebruik...
Nederlands 4.3 Mogelijke confi guraties van de latere versie van de CTC EcoZenith Mogelijkheid 1 Latere CTC EcoZenith CTC Converter Warmtepomp Warmtepomp Instellen: F1 Versie 3 Versie 3 A1 = Geeft type weer Instellen: A Instellen: A Warmtepomp Versie 4...
Instellen: A1 (fabrieksinstelling) Instellen: A1 (fabrieksinstelling) Instellen: A1 (fabrieksinstelling) Let op: de warmtepompen moeten op de afgesloten positie zijn ingesteld 4.4 Mogelijke confi guraties van de CTC EcoEl CTC EcoEl CTC Converter Instellen: F1 A1 = Geeft type weer Warmtepomp...
5. Functies 5.1 Algemeen AAN gaat branden wanneer de CTC Converter wordt ingeschakeld. RS485 TX knippert wanneer de CTC Converter naar een warmtepomp zendt RS485 RX knippert wanneer de CTC Converter van een warmtepomp ontvangt COM TX knippert wanneer de CTC Converter naar de EcoEl/Ecologic/...
Controleer ook het captatiepompfilter dat is geïnstalleerd. Als de storing opnieuw optreedt, neem dan contact op met uw installateur. De combinatie CTC Converter met CTC EcoPart 400 kan een alarm veroorzaken. Verhelp dit door de sensor captatie in / captatie uit te vervangen.
Als de storing optreedt, neem dan contact op ventiel met uw installateur. Communicatiefout tussen Dit bericht verschijnt wanneer de CTC Converter niet kan communiceren de CTC Converter en de met de warmtepomp(en) warmtepomp Dit bericht verschijnt wanneer de CTC Converter niet kan communiceren...
Norsk Norsk Installasjons- og vedlikeholdsanvisning CTC Converter VIKTIG LES NØYE FØR BRUK OPPBEVAR TIL FREMTIDIG BRUK CTC Converter...
Page 122
Versjon 3 og 4 __________________________________________________ En eller tre kommunikasjonsklemmer _______________ Installasjon _______________________________________________________ CTC EcoLogic og CTC EcoZenith i550 med én kommunikasjonsklemme ________________________________ CTC EcoZenith i550 / CTC Ecologic EXT med tre kommunikasjonsklemmer _______________________________ CTC EcoEl V3 ______________________________________________ CTC EcoLogic ______________________________________________ CTC EcoZenith _____________________________________________...
Page 123
Norsk Generelt Med CTC Converter kan varmepumper med versjon 4 kobles til versjon 3 (V3) av CTC EcoEl, CTC EcoLogic, CTC EcoLogic EXT og CTC EcoZenith i550. Varmepumper versjon 4 (V4) CTC EcoAir 406 CTC EcoPart 406 CTC EcoAir 408 CTC EcoPart 408...
584890001 CTC EcoZenith I 550 BBR 7250-1222-0172 584893001 CTC EcoZenith I 550 1x230V I den nyere utførelsen trenger man en CTC Converter til hver varmepumpe av versjon 4. Versjon 3 og 4 CTC Converter «oversetter» styringen fra versjon 3 (V3) til varmepumpe versjon 4 (V4).
Page 125
1 isoleringsslange Ø10 mm 4 skruer CTC EcoEl V3 1 stk. matekabel for CTC EcoEl V3, 2,5 m 1.L1 2.Com Som kommunikasjonskabel til CTC EcoPart 400 må du bruke LiYCY (TP). LiYCY (TP) er en 4-leder med skjerm, der kommunikasjonsbærende leder er tvunnet. CTC Converter...
Ta ikke på kretskortets komponenter. Kretskortet / styres fra CTC kan skades av statisk utlading EcoAir 400, er det stor risiko for alvorlig skade på varmepumpen. 2.1 CTC EcoLogic og CTC EcoZenith i550 med én kommunikasjonsklemme strømsentral Brun Hvit Varmepumpe Grønn Bøyle CTC EcoLogic V3...
Varmepumper versjon 4 (CTC EcoPart 400 og CTC EcoAir 400) leveres innstilt som A1. I konfigurasjoner med mer enn en varmepumpe av versjon 4 må denne stilles inn som A2 eller A3. CTC EcoPart XL består av 2 varmepumper som fra fabrikken er stilt inn som: • Den øverste A2 •...
Page 130
Norsk Alternativ 2 CTC EcoLogic og tidlig CTC EcoZenith Kun CTC EcoLogic CTC Converter Varmepumpe MiniEl Innstilt: F2 Versjon 3 Versjon 3 A1 = Viser type Innstilt: A3 A2 = Viser type A3 = 0 Brukes ikke Varmepumpe Varmepumpe OBS: Det er bare varmepumpen...
Norsk 3.3 Mulige konfi gurasjoner i den senere utførelsen av CTC EcoZenith Alternativ 1 Senere CTC EcoZenith CTC Converter Varmepumpe Varmepumpe Innstilt: F1 Versjon 3 Versjon 3 A1 = Viser type Innstilt: A Innstilt: A Varmepumpe Versjon 4 Innstilt: A1 (Fabrikkinnstilling)
OK i mer enn 3 sekunder velger den viste varmepumpen. Med pilene kan du øke/redusere den viste verdien. 0 = Varmepumpen frakoblet, brukes ikke. Se: Note 1. Hvis verdien økes, vises ”-” til CTC Converter har lest inn typen fra varmepumpen 1 = Varmepumpen er av type EcoPart 2 = Varmepumpen er av type EcoAir Når du trykker på...
Kontroller også installert brinefilter. Ved tilbakevendende feil – ta kontakt med installatøren. I kombinasjon med CTC Converter og CTC EcoPart 400 kan det oppstå falsk alarm. Dette kan løses ved å bytte plass på sensorene Brine inn og Brine ut.
Det vises tekst når CTC Converter ikke kan kommunisere med Kommunikasjonsfeil mellom CTC Converter og varmepumpe/r varmepumpe Kommunikasjonsfeil Det vises tekst når CTC Converter ikke kan kommunisere med EcoEl/ EcoLogic/EcoZenith mellom CTC Converter og EcoEl/EcoLogic/ EcoZenith 6. Informasjonstekster For å beskytte kompressoren finnes det situasjoner når styringssystemet stopper kompressorens drift, og da vises det også...
Verantwortung, dass das Produkt, CTC Converter som omfattas av denna försäkran är i överensstämmelse med följande direktiv, auquel cette déclaration se rapporte est en conformité avec les exigences des normes...