13. SPECIFICATIONS
DC input voltage
Output power
Output power surge
Battery-high shutdown
Battery-low alarm
Battery-low shutdown
Short circuit protection
No-load current
Alarm and thermal shutdown
DC input fuse
Dimensions (L x W x H)
Net weight
AC output voltage
Frequency
AC output socket
AC output socket
PI150W // 12V & 24V
DC 10-15V (12V) // DC 20-30V (24V)
150W
450W
15.5 ± 0.5V (12V) // 30 ± 1V (24V)
10.5 ± 0.5V (12V) // 21 ± 1V (24V)
10 ± 0.5V (12V) // 20 ± 1V (24V)
yes
< 0.3A
60° C ± 5° C
20A (12V) // 10A (24V)
165 x 91 x 58mm
0.85kg
230V
50Hz
PI150MN // PI15024MN
PI150BN // PI15024BN
6