Télécharger Imprimer la page

Installation Instructions - Presto 60358 Notice D'installation

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
ENGLISH

1) INSTALLATION INSTRUCTIONS

2) PRESTO HEALTH – AUTOMATIC HAND-DRYER Part no. 60358
3) Operation:
-Instantaneous activation after placing hands under the air terminal device.
-Automatic shut-off as soon as the hands are removed
-Anti shut-off safety: Automatic shut-off after 1 min of continuous detection.
Characteristics:
-Power 1650 W
-Weight = 3Kg
-Supply voltage = 230VAC – 50 Hz
-Insulation class II
-Motor 2500 rpm
-Air speed = 11 m/s
-Flow: 120m3/h
-Detection distance = from 50 to 200 mm
- Automatic shut-off after 1 min of continuous operation.
-Sound level < 70 dB
-Selector switch situated on the rear face used to lock the heating.
-Delivered with screws + dowel pins.
4) Installation instructions:
-The electrical connection must be carried out by authorised personnel.
-The exhaust opening must be situated at approximately 1.3 metres from the ground.
-No obstacle must be situated at less than 30cm from the base of the device.
-The hand-dryer must be connected to a protected line of minimum 10 amperes rating.
-In case of use in a bathroom, the hand-dryer must be beyond the reach of a person using a
bath tub, or a shower, (outside the safety volume 2).
- Disconnect the electrical receptacle of the hand-dryer before any intervention inside the
hand-dryer.
Installation instructions:
-Remove the front face after having removed the 2 screws located under the front face.
-Apply the plumb frame on the partition according to the installation instructions, then point
using a marker the position of 4 mounting holes of pins.
-Drill the 4 holes Ø8, then fix the pins.
-Install the frame, then the front face in the reverse order to that of removal.
-Connect the power connector.
-Place the selector switch in position 1.
Thermal safety:
-In case of plugging of the air flow, the thermal safety stops the heating.
-It gets rearmed after the fault disappears.
Maintenance:
-Place the selector switch in position 0 in case of prolonged disuse.
-Disconnect the hand-dryer plug to clean the front face (clean with a slightly damp cloth).
5) This document is not contractual, we reserve the right to modify the characteristics of our
products without notice.
6) PATENTED and REGISTERED MODELS