If you are unable to move the hanging tool up or down using moderate force, DO NOT continue but contact our technical service at once.
NOTE: the balancer locks even if the drum spring is completely discharged. To restore working efficiency, attempt
to charge the spring as outlined in paragraph "Adjusting the balancer". If the balancer does not release, DO NOT do
anything but contact the technical service at once.

INSPECTIONS AND MAINTENANCE

ATTENTION: check the condition of the ground cable and the tightening of the screw
regular basis (for instance, once after every work shift) and carefully remove dust so that it will not build-up, i.e.
not more than 5 mm.
ATTENTION: replace the drum every 100,000 (hundred thousand) cycles.
Maintenance may be carried out only by skilled and authorized personnel.
- The user must visually inspect the balancer on a regular basis (such as, for instance, at each work shift) especially to check
the state of suspensions (A) and (S) (Fig.1), the fixing screws and the self-locking systems (if used), and the condition of the
hooks and cable.
Should the cable have the defects shown in (Fig.8), replace it immediately.
Do not make any modification to the cable unit and, specifically, DO NOT SHORTEN the cable: if need, please get in touch with
TECNA S.p.a.
- check that the cable's movement is smooth and that it does not make any strange noises;
- do not lubricate the balancer with flammable or volatile fluids;
- do not remove any labels. Replace any damaged labels;
- the balancer must be inspected at least once a year by skilled, authorized personnel.
Never disassemble the balancer. Maintenance is to be carried out only by skilled, authorized personnel.
The static and dynamic tests (Machinery Directive 2006/42/EC, Annex I, section 4.1.3) have been performed by the manufacturer.
The balancer must be disposed of complying with prevailing rules and regulations at the end of its work life.
Warranty
The use of non-original TECNA spare parts will negatively affect safety and performance and will, in any case, void
the warranty.
ATTENTION: The cable and the drum spring are not covered by the warranty.