Stopping The Generator; Oil Sensor; Troubleshooting; Troubleshooting Chart - BEPOWEREQUIPMENT BE12000ES Mode D'emploi

Table des Matières

Publicité

STOPPING THE GENERATOR

Stopping The Generator
1. Turn off the power switch of the electric equipment and unplug the
cord from receptacle of the generator.
2. Allow the engine about 3 minutes to cool down without load before
stopping.
3. Push the engine switch to the OFF position.
4. Push the main switch to the OFF position.

Oil Sensor

The oil sensor detects a drop in oil level in the crankcase and
automatically stops the engine when the oil level drops below a
predetermined level.
When the engine has stopped automatically, turn off the generator, and
check the oil level. Drain any excess oil and then refill to the upper level
as instructed and restart the engine.
CAUTION
DO NOT remove oil sensor probe when refilling with oil.
Remove oil filler cap on the opposite side of carburetor.
24

TROUBLESHOOTING

Troubleshooting Chart

If you are experiencing a problem that is not listed in this chart, or have
checked all the possible cause listed and you are still experiencing the
problem, see your authorized dealer.
Problem
Cause
1. Circuit breaker is open.
Engine is running,
2. Poor connection or defective cord.
but no AC output is
3. Connected device is bad.
available.
4. Fault in generator.
5. GFCI on control panel is tripped.
Engine runs well
1. Short circuit in a connected load.
but slows down
2. Generator is overloaded.
when loads are
3. Engine speed is too slow.
connected.
4. Shorted generator circuit.
1. Fuel shut-off is OFF.
2. Air filter is dirty.
3. Out of gasoline.
4. Stale/Expired gasoline.
5. Spark plugs not connected.
Engine will not
6. Bad spark plugs.
start, or starts and
7. Water in gasoline.
then runs poorly.
8. Over-choking.
9. Low oil level
10. Excessively rich fuel mix.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. Fuel has run out.
Engine shuts down
2. Dirty air filter.
during operation
3. Fault in engine.
1. Load is too high.
Engine lacks power
2. Dirty air filter.
3. Engine needs to be serviced.
1. Choke is opened too soon.
Engine falters
2. Carburetor is running too rich or
too lean.
Correction
1. Reset circuit breaker
2. Check and repair.
3. Connect another device that is in
good condition.
4. Contact authorized service facility.
5. Verify ground connections.
1. Disconnect shorted electrical load.
2. See "Overloading Generator" section.
3. Contact authorized service facility.
4. Contact authorized service facility.
1. Turn to "ON".
2. Clean or replace air filter.
3. Fill fuel tank.
4. Drain fuel tank and fill with fresh fuel.
5. Connect wire(s) to spark plugs.
6. Replace spark plugs.
7. Drain fuel tank; fill with fresh fuel.
8. Move knob to "no choke" position.
9. Fill crankcase to proper level.
10. Contact service facility.
11. Contact service facility.
12. Contact service facility.
1. Fill fuel tank.
2. Clean or replace air filter.
3. Contact authorized service facility.
1. Reduce load.
2. Clean or replace air filter.
3. Contact authorized service facility.
1. Move choke to halfway position until
the engine runs smoothly.
2. Contact authorized service facility.
25

Publicité

Table des Matières
loading