OPERATION

Using Electric Power

WARNING
Risk of electrocution.
Make sure that the appliance is switched off before
connecting it to the generator.
• DO NOT move the generator while it is running.

AC Application

1. Make sure the voltage indicated on the voltmeter is at the normal level
(approx. 120V).
NOTICE
This generator is thoroughly tested and adjusted in the factory. If the
generator does not produce the specified voltage, consult your nearest
authorized service provider.
2. Turn off the switch(es) of the electrical appliance(s) before connecting
to the generator.
3. Insert the plug(s) of the electrical appliance(s) into the receptacle.
• Be sure that the total wattage of all connected appliances does
not exceed the rated output of the generator.
WARNING
To take power from the twistlock receptacle, insert the
plug into the receptacle, and turn it clockwise to the
lock position.
• DO NOT put foreign objects into the plug receptacle.
4. Turn on the switch of the appliance.
20
OPERATION

DC Application

The DC terminal is used for trickle charging 12 volt batteries or low
amperage drawing DC tools or appliances.. It provides 12V - 8.3A
(100W) of maximum power.

Connection of Cable

Connect positive terminal (red) on generator to positive (+) terminal on
battery.
Connect negative terminal (black) on generator to negative (-) terminal on
battery.
Safety Precautions While Charging a Battery
WARNING
An explosive hydrogen gas is discharged through vent
holes in the battery during the charging process. Do not
allow spark or open flame around the generator or
battery during the charging process.
Electrolyte fluid can burn eyes and clothing. Be careful to avoid
contact. If injured, wash the affected area immediately with large
quantities of water and consult a doctor for treatment.
When charging a large capacity battery or totally discharged battery,
excessive current may force the DC breaker to turn off.
In such cases, use a battery charger to charge a large battery with AC
output.
Battery defects may cause the DC breaker to trip. Check the battery
before resetting the DC breaker.