Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

COIL MOUNT
CLAMP PLATE Z-BRACKET
ALSO INCLUDED
Rev 5
PCO BRACKET
BALLAST
TECH MANUAL
STEEL DUCT
MOUNT
DUCTBOARD
MOUNT
HARDWARE KIT
INSTALLATION
GLOVES
UVC 2YR LAMP
SERVICE LABEL
Issued: 05/01/2019
DUCTBOARD
PLATE

Publicité

loading

Sommaire des Matières pour Second Wind 2414-PREMIUM

  • Page 1 COIL MOUNT STEEL DUCT MOUNT DUCTBOARD MOUNT DUCTBOARD CLAMP PLATE Z-BRACKET PCO BRACKET UVC 2YR LAMP PLATE • ALSO INCLUDED HARDWARE KIT • • • BALLAST INSTALLATION SERVICE LABEL • TECH MANUAL GLOVES Rev 5 Issued: 05/01/2019...
  • Page 2: Recommended Tools

    Check damaged parts: Before further use of the unit, any damaged part should be carefully checked to ensure that the unit will operate properly. Any part that is damaged should be properly repaired or replaced. Always service unit with Second Wind replacement parts & recommended accessories (i.e. lamps, ballast). CAUTION: Disconnect power before starting installation or maintenance.
  • Page 3 PRE-ASSEMBLY INSTRUCTIONS—OVER THE COIL INSTALLATION STEP 2 - PUT RUBBER GLOVES ON HANDS - REMOVE LAMP FROM PACKAGING - CAREFULLY INSERT LAMP INTO Z-BRACKET ’ FIGURE 8’ CUT-OUT IN ORIENTATION SHOWN STEP 1 - INSTALL PCO BRACKET ON Z-BRACKET PEM STUDS - SECURE WITH HEX NUTS - INSTALL SELF TAP SCREW IN TOP OF PCO BRACKET STEP 4...
  • Page 4 INSTALLATION: Prime location for installation of this device is on the supply side duct just above the condensing coil (aka A-coil, slab coil, etc), but it can be installed on the return side if necessary. See Figures below. Follow Pre-Assembly instructions on page 3 Disconnect air handler from supply power.
  • Page 5 The Second Wind Ultraviolet Germicidal 24 Volt Lamp is designed for 14000-16,000 hours of continuous opera- tion. After 16000 hours (approx 22 months) intensity of the lamp inside the duct diminishes and should be re- placed. Ballast# 010303 will display need for lamp change. Replacement of the lamp is recommended by a quali- fied HVAC Service Technician.
  • Page 6 Failure to provide maintenance per these instructions will void warranty. This warranty will be voided if the covered equipment (only Second Wind replacement parts or units are warranted) is removed from the original installation site. This warranty does not cover damage or defect resulting from: Accident, or neglect or unreasonable use or operation of the equipment, including operation of electrical equipment at voltages other than the range specified on the unit name plate.
  • Page 7 FIXATION FIXATION CONDUIT EN ACIER FIXATION PANNEAUX DE CON- PLAQUE DE PLAQUE DE SUPPORT-Z SUPPORT LAMPE UVC CONDUIT SERRAGE 2-ANS AUSSI INCLUS L’ENSEMBLE DE • BALLAST QUINCAILLERIE TION • GANTS DE PROTEC- ÉTIQUETTE DE • • • MODE D’EMPLOI...
  • Page 8: Outils Recommandés

    AVERTISSEMENT: NON-RESPECT DES CONSIGNES PEUVENT RÉSULTÉ EN DE GRAVES BLESSURES Lisez le mode d’emploi attentivement; non-respect des consignes pourrait endommagé ce produit ou causer une situation dangereuse. Installateur doit être un technician de service formé et expérimenté Risque de lumière UV. Nocif à la peau nue et aux yeux. Le rayonnement UV peut causer la perte de vision temporaire ou permanent.
  • Page 9 CONSIGNES PRÉ-MONTAGEs — INSTALLATION SUR-BOBINE ÉTAPE 2 - ENFILER DES GANS DE CAOUTCHOUC SUR LES MAINS - RETIRER LA LAMPE DE SON EMBALLAGE - INSÉRER AVEC PRÉCAUTION LA LAMPE DANS LE SUPPORT-Z ORIENTER LE DÉCOUPE ‘FIGURE ÉTAPE 1 8’ COME DÉMONTRÉ - INSTALLÉ...
  • Page 10 INSTALLATION: Endroit preferable pour l’installation de cet equipment est sur le côté avec le conduit d’alimentation juste par dessus du serpentin de condensation (bobine-A, bobine à dalle, etc), cependant il est possible de installer sur le côté du conduit de retour, si necessaire. Voir les figures en bas. Suivez les Consignes Pré-montage à...
  • Page 11 La lampe germicide ultraviolette à 24 Volts de Second Wind à été conçu pour un fonctionnement constant de 14000-16,000 heures. Après 16000 heures (environs 22 mois) l’intensité de la lampe dans le conduit diminue et dois être remplacé. Ballast# 010303 va affiché le besoin pour le remplacement. C’est conseillé d’avoir un techni- cian de système CVC formé...
  • Page 12 La faillite d’assurer l’entretien selon les consignes annulera la guarantie. Ce guarantie sera annuler si l’équipment assuré (seulement les pieces de remplacements ou appareils Second Wind sont assures) est retirer du site originale de montage. Ce guarantie n’assure pas des endommages ou des défauts causer par: Accident, ou negligence ou d’usage déraisonnable ou de l’utilisation de l’apparail, ce qui inclue l’utilisation d’équipment électrique à...