TERWA USER INSTRUCTIONS FOR TORQUE WRENCH (ARTICLE 47818)
The Terwa Torque Wrench has been specially designed to ensure the correct mounting of the Rebar Connection System.
The technical approval on the Terwa Rebar Connection System is based upon the fact that connections are tightened to
the correct torque settings. Only correctly mounted rebar connections can be loaded to their full capacity.
Read these instructions carefully before use.
Calibration:
The torque wrench is delivered with a calibration report. This report should be carefully kept with your safety documents
and work instructions. The calibration becomes valid on the date the tool is first used. It should be recalibrated
periodically as mentioned in the original calibration certificate. Periodic recalibration should only be carried out by local
accredited companies, and according to the control procedure that is mentioned on the original calibration certificate.
1.
Rebar pliers.
2.
Adjustment and pull handle.
3.
Adjustment ring for opening and closing the pliers.
4.
List of torque values per rebar size.
General remark:
•
This wrench is a calibrated piece of equipment and should be handled with care.
•
This torque wrench should be stored in a dry place.
•
Before each use, the wrench should be checked for damages. Any damage to the adjustment handle and the
wrench shaft requires that the tool be recalibrated.
•
When stored, the torque wrench handle should be turned back to the lowest possible value.
1
2
Copyright Terwa Construction Group 2005 - 2022 © | www.terwa.com