1. Aquameter Delivery Scope
Display (fig. 1 and fig. 2)
a.
"PROG" button
Indicator
b.
"RESET" button
c.
Covering
d.
Cable, 1.5 m
e.
Screw
f.
Housing
g.


Button cell 3VDC, type CR2032
h.
2. Technical Data
Sensor Unit Technical Data:
Connection thread (IN/OUT)
Intake pressure (min/max)
Flow capacity
Pressure loss (up to 100 l/h flow rate)
Flow rate deviations
Water temperature (min/max)
Ambient temperature (min/max)
Dimensions (L×W×H)
Installation position
External Display Technical Data:
Splash water-proof:
Static memory:
Indicator:
Counter:
Installation position
Dimensions (L×W×H)
Cable:
Aquameter order number
3. Explanation of Display Symbols and Significance
"PROG" button: – for adjusting
l.
settings
– for exiting the Programme mode
"RESET" button: – for resetting
m .
the filter capacity after every bestmax
filter cartridge replacement
– for adjusting settings
BATT: Battery change indicator
n.
OF: OverFlow indicator
o.
Appears when the value of -99999 has
been exceeded.
Sensor unit (fig. )
i.
Plastic housing with C\," nut and
C\," external thread
Gasket (no illustration)
j.
Sensor
k.
Note: Remove the hygiene protection
on the inlet side and outlet side prior
to installation.
[inches] /" nut × /" connection thread
[bar] 2– bar
[l/h] 10–100
[bar] 0.2
[%] +/- 5
[°C] +4 to +40
[°C] +4 to +0
[mm] 77 × 4 × 46
Horizontal recommended
IP X4
5 most recent null positions
5 digits
[l/min] Downwards from  to -
Horizontal recommended
[mm] 62 × 50 × 17
1.5 metres, PVC 2 × 0.25 mm²
FS00Y0A00
PRG: Appears when the
p.
water+more Aquameter is program-
med
1245: Memory information
q.
It is possible to access the 5 most re-
cent measurements.
The capacity in litres [L] and the time
period [t] are displayed for each case.
5-digit indicator
r.
4. General Information
Scope of application
The water+more Aquameter was developed to measure and monitor the residu-
al capacity of water+more water filters. After entry (see Section 6) of the respec-
tive filter capacity (see Installation and Operating Instructions bestmax), the Aq-
uameter calculates the relative residual capacity.
This ensures timely replacement of the water+more water filter.
The installed LCD indicator informs the user of the residual capacity of the
water+more water filter.
Safety regulations
1. Read through the Operating Instruc-
tions carefully before the start of op-
eration. Perform all steps exactly as
indicated in the instructions.
2. Adhere to all directions and illustra-
tions.
. Only use standard batteries of the
type CR2032.
4. Ensure that the battery cover is
properly fitted. Otherwise, debris
and moisture could penetrate.
5. In the following cases, the pow-
er supply must be disconnected im-
mediately (remove battery) and a
technician must be called:
Water or other liquids have pene-
trated into the appliance
The appliance does not function prop-
Installation information
No rapidly pulsating medium stim-
ulus
No pressure reversals
No air in the system
Take the installation position of the
Aquameter into account
Min/max. flow rate should lie in the
linear area of the selected Aquameter
Appropriate and periodic cleaning
Self-declaration:
The water+more Aquameter meets the mandatory CE guidelines.
erly even though all of the directions
provided in these Operating Instructions
have been adhered to exactly
If the appliance falls and the housing
is damaged
If the indicator of the appliance does
not function
If the PROG or RESET buttons do not
function
Do not attempt to repair anything your-
self or to accomplish anything by ran-
domly pressing the PROG or RESET but-
tons.
If there is no power supply, the installed
electronics assembly will not function. If
the appliance is operated without a bat-
tery or with a depleted battery, it is not
possible to make any measurements.
Protect the battery and electrical con-
tacts from moisture
Inductive malfunctioning must be
avoided
The number of impulses per litre may
vary according to medium and in-
stallation
We recommend calibration of the im-
pulse/litre value with the overall in-
stallation