COLUMN PROGRAMMING
P
rogramming the converter.
In case of using this module as a column encoder (see page 26), a different column code must
be programmed in every converter, following these steps:
golmar
1
0
0
In case of more converters, proceed equally introducing a different column code in each
converter.
If the red led lights up during any of these procedures, restart the programming mode from the
beginning.
13:15
Activate the converter programming: set to ON the switch
number 1.
The door panel emits a tone and the green led of the
converter starts a slow blinking. It means the
programming has begun.
0
Introduce the column code to be programmed followed by
O.K.
three zeros, then press the bell button.
The door panel will emit some tones to show it has been
correctly programmed.
To exit the programming mode, set to OFF the switch
number 1 and press the Cancel button of the door
panel.
Access into the panel programming mode by
pressing the key button followed by the secret code
of installer (factory default 1315), as it is shown on
the door panel manual.