CAUTIONS
During cold weather, protect finished work from traffic until
■
■
fully cured.
For white and light-colored marbles, use a white polymer fortified
■
■
portland cement thin set mortar.
For green and moisture sensitive marble, agglomerates and resin
■
■
backed tile and stone use LATAPOXY
Data Sheet 633.0).
If the waterproof coating on the HYDRO BAN Pre-Sloped or
■
■
Preformed product is punctured during installation or from job site
construction activity re-coat the punctured area and 2" (50 mm)
around the area with two coats of HYDRO BAN, follow DS 663.0
or DS 663.5 for full instructions.
Use care not to damage surface of HYDRO BAN Pre-Sloped or
■
■
Preformed products prior to installation of tile or stone finishes.
Cover with protection board to protect from foot traffic and
other trades.
HYDRO BAN Drain Grate
254 Platinum
Concrete
300 Adhesive (refer to
®
DETAIL: ES-WP313
3
WATERPROOFING BARRIER FREE SHOWER INSTALLATIONS
Shower walls with cement backer board construction can be
waterproofed using either HYDRO BAN liquid applied waterproofing
membrane following the respective data sheet and installation guide
DS 663.0 and DS 663.5 or HYDRO BAN Sheet Membrane following
data sheets and installation guides DS 041.0, DS 043.5.
INSTALLATION
INSTALLATION OVER CONCRETE OR WOOD JOIST
SUPPORTED FLOORING
The HYDRO BAN Pre-Sloped Shower Pan can be installed over a
concrete or wood joist supported floor along with a HYDRO BAN
Pre-Sloped Ramp. Follow the recommendations in detail ES-WP313
below and the data sheets for the installation of the HYDRO BAN
Pre-Sloped Shower Pan DS 031.0 and the HYDRO BAN Pre-Sloped
Ramp DS 063.0 to create a barrier free or ADA compliant shower.
DETAIL: ES-WP313
SPECTRALOCK
HYDRO BAN Pre-Sloped Ramp
PRO Premium Grout
®
HYDRO BAN
®
4-XLT
HYDRO BAN Pre-Sloped Shower Pan