Access Control Panel Connections - Schlage GWE Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Gateway
Gateway
Connector
+
Power
Rx –
Tx –
RS485
Rx +
Tx +
GND

Access Control Panel Connections

Access control
panel signal
12 or 24 VDC
DC Ground
– Receive Data
– Transmit Data
+ Receive Data
+ Transmit Data
Signal Ground
Description
Gateway inputs for 12 or 24 VDC power.
Draws 250mA max.
If the Access Control Panel (ACP) reader
power outputs do not source enough current
for the Gateway, use the ACP main regulated
12 VDC power supply or a separate UL294
Listed 12 or 24 VDC power-limited power
supply.
Power input is non polarized.
4-Wire or 2-Wire bi-directional RS485
communication port for interface to Access
Control Panels.
2-Wire installation: Both 2|4 wire jumpers
should be added.
4 -Wire installation: Both 2|4 wire jumpers
should be removed.
Refer to following pages for typical wiring
diagrams.