18
Product No. 085-1578-8 | Model No. FHTS80048C
Step 5
Connecting LP Gas Tank
K
Required Piece:
1. Before connecting, be sure there is no debris caught head of the LP gas tank,
head of the regulator valve or in the head of the burner or burner ports.
2. Connect the propane hose assembly to tank by turning knob clockwise until
it stops.
Step 6
Disconnecting LP Gas Tank
K
Required Piece:
1. Before disconnecting make sure the LP gas tank valve is "CLOSED".
2. Disconnect regulator/hose assembly from LP gas turning knob
counter-clockwise until it is loose.
3. Place the protective cap cover on LP tank and store the tank outdoors in
a well-ventilated area out of direct sunlight.
Caution: LP gas tank must be properly disconnected and removed prior to
moving this table.
Step 7
Checking for Leaks
WARNING: Before using this outdoor fireplace, make sure you have read, understand
and are following all information provided in the "Important Safeguards" section.
Failure to follow those instructions can cause death, serious injury or property damage.
Failure to inspect this connection or follow these instructions could cause death,
serious bodily injury or damage to property.
Checking Burner Connections
1. Make sure the regulator hose and valve connections are securely fastened to the
K
burner and the tank.
2. Visually check the connection between the burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the orifice.
4. Please refer to diagram (figure 1 and 2) for proper installation.
5. If the burner/venturi tube does not rest flush to the orifice, as shown (figure 1 and 2),
please contact 1-888-670-6684 for assistance.
Step 8
Leak Test
1. Make 2-3 oz of leak detection solution by mixing one part liquid dishwashing
soap with three parts water.
2. Make sure control knobs are in the "OFF" position.
3. Connect LP gas tank per "Installing LP Gas Tank" section.
4. Turn LP gas tank valve to "OPEN ".
5. Spoon several drops of solution, or use a squirt bottle, at all "X" locations (figure 1
and 2).
K
WARNING:
this connection or not
follow these instructions
could cause death, serious
bodily injury or damage to
property.
a. If any bubbles appear, turn LP gas tank valve to "CLOSED", reconnect
and re-test.
b. If you continue to see bubbles after several attempts turn LP gas tank
valve to "CLOSED" and disconnect LP gas tank, per "Disconnecting LP Gas
Tank". Contact 1-888-670-6684 for assistance.
c. If no bubbles appear after one minute, turn LP gas tank valve to
"CLOSED", wipe away solution proceed.
Figure 1
Failure to inspect
19
Figure 2
OFF