4.5 Changing the ControlSystem
If it is necessary to replace the ControlSystem
system that is already linked, you will need to de-
system that is already linked, you will need to d
lete the old serial number before linking the new
lete the old serial number before linking the new
one.
To do this, with the SilenPlus pump connected to
the power supply, keep the F button
for 10 seconds. Flashing LEDs indicate that the
for 10 seconds. Flashing LEDs indicate that the
operation has been carried out correctly.
operation has been carried out correctly.
The previous serial number will be deleted and the
The previous serial number will be deleted and the
system will go into "link standby" mode. Proceed as
system will go into "link standby" mode. Proceed as
indicated in 4.2.2.

5. OPERATION

5.1 REMOTE mode

This is the default operating mode.
The pump carries out the most appropriate function
The pump carries out the most appropriate function
considering the position of the filter valve. (See
considering the position of the filter valve. (See
figure 3)
• In FILTRATION position: Filtration Plus
• In BACKWASH position: Backwash
• In CLOSED position: pump stopped.
sition: pump stopped.
• In any of the other positions: the pump operates
In any of the other positions: the pump operates
at 100% power.
• When you operate the valve control, the pump
When you operate the valve control, the pump
stops automatically to make the valve movement
stops automatically to make the valve movement
easier.
• In any intermediate position, the pump remains
In any intermediate position, the pump remains
stopped.
To change the working mode, simply move the
working mode, simply move the
valve to the desired position.
To prevent accidental operation, the elec-
To prevent accidental operation, the ele
tronic response is delayed by 1 second. The
tronic response is delayed by 1 second. The
flashing red LED indicates that proper co
flashing red LED indicates that proper com-
munication has been achieved.
munication has been achieved.
Move the valve gently.
WARNING: the valve configuration must corr
the valve configuration must corre-
spond to the 6 standard positions, according to
spond to the 6 standard positions, according to
figure 3.
For other valve configurations, contact your techn
For other valve configurations, contact your techni-
cal service.

5.2 MANUAL mode

When you press the M, key SilenPlus
ControlSystem signal and runs one of the preset
signal and runs one of the preset
functions:
The MAN LED comes on.
The pump starts up at a fixed, programmable speed.
The pump starts up at a fixed, programmable speed.
The standard setting is 2,300 RPM (40 Hz). This is
The standard setting is 2,300 RPM (40 Hz). This is
what is known as the MIXED CYCLE (MISC.
what is known as the MIXED CYCLE (MISC.
CYCLE).
If you press the F key, it runs throug
key, it runs through the various
SilenPlus functions in sequence.
Between each function, the pump stops to allow
Between each function, the pump stops to allow
valve movement or other operations.
valve movement or other operations.
ControlSystem in a
pump connected to
button pressed down
Filtration Plus function
Backwash Plus function
SilenPlus ignores the
The sequence is:
1. Mixed cycle (MISC. CYCLE).
Mixed cycle (MISC. CYCLE).
2. Stop.
3. Filtration Plus.
4. Stop.
5. Backwash plus.
6. Stop.
7. Mixed cycle...
The lit LEDs indicates the function selected at all
indicates the function selected at all
times.
When you press the M button again, you leave
Manual mode to go back to Remote.
Manual mode to go back to Remote.
5.3 No water fault and retries.
5.3 No water fault and retries.
In Filtration Plus mode, the system is regularly
mode, the system is regularly
monitored to check that the pump is not operating
tored to check that the pump is not operating
without water.
If SilenPlus detects the pump is working without
detects the pump is working without
water it stops the motor.
The system will attempt to start up again after 1', 5',
The system will attempt to start up again after 1', 5',
15' and 1 hour (Fig. 4). If the retries fail,
remain in permanent fault mode.
remain in permanent fault mode.
An LED sequence indicates the fault status. (See
An LED sequence indicates the fault status. (See
figure 7)
To interrupt the retry cycle or to restart from perma-
To interrupt the retry cycle or to restart from perm
nent fault mode, press the F

5.4 System status

Espa offers installers and users the EspaEvopool
Espa offers installers and u
application for monitoring the system status and
application for monitoring the system status and
interacting with SilenPlus.
You need to have an Android device with
You need to have an Android device with
Bluetooth connectivity and the EspaEvopool
Bluetooth connectivity and
app available from
With this app, it is possible to switch between
With this app, it is possible to switch between Man-
ual/Remote modes and use all functions.
modes and use all functions.
6. ADVANCED CONFIGURATION
6. ADVANCED CONFIGURATION
Different speeds can be set to adjust the functions
Different speeds can be set to adjust the functions
to the characteristics of the installation.
to the characteristics of the installation.
The function being run will be configured.
The function being run will be configured.
To configure a function, first select it, either in Man-
To configure a function, first select it, either in Ma
ual or Remote mode, and at the same time press M
ual or Remote mode, and at the same time press
+ F for 5 seconds.
All the speeds of the selected function will return to
All the speeds of the selected function will return to
the factory settings [= fs]
To increase or decrease the speed, press M or F:
To increase or decrease the speed, press M or F:
M = + 58 RPM (+ 1 Hz)
F = - 58 RPM (- 1 Hz)
• Configuring Filtration Plus
Filtration Plus.
The filtration speed is set.
The filtration speed is set.
· Minimum = 1,600 RPM (20 Hz), [= fs]
· Minimum = 1,600 RPM (20 Hz), [= fs]
· Maximum = 2,900 RPM (50 Hz), [= fs]
· Maximum = 2,900 RPM (50 Hz), [= fs]
10
EN
button again, you leave
he retries fail, Evopool will