Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

PS1202C, PS2402C
Replacement Power Supply Kits
for Electronic Air Cleaners
APPLICATION
These kits replace the power supplies with solid-state
performance indicators (SSPI) used in the F50, F52,
F57, and F90 Electronic Air Cleaners. See Table 1. Each
kit includes the power supply and leadwires.
Supply
Model
Voltage
F50E
120 Vac
240 Vac
F52E (One
120 Vac
Cell)
220-240
Vac, 50 Hz
F52E (Two
120 Vac
Cell)
220-240
Vac, 50 Hz
F57A (Two
120 Vac
Cell)
220-240
Vac, 50 Hz
F57B (One
120 Vac
Cell)
220-240 Vac
F90A (Two
120 Vac
Cell)
220-240
Vac, 50 Hz
F90B (One
120 Vac
Cell)
220-240
Vac, 50 Hz
F52F (One
120 Vac
Cell)
220-240
Vac, 50 Hz
F52F (Two
120 Vac
Cell)
240 Vac
Table 1. Power Supply Replacement Guide.
Nominal Size of
Electronic Cell(s)
(in.)
(mm)
16 x 25
406 x 635
20 x 20
508 x 508
20 x 25
508 x 635
16 x 25
406 x 635
20 x 20
508 x 508
20 x 25
508 x 635
20 x 12-1/2 508 x 318
20 x 25
508 x 635
20 x 25
508 x 635
20 x 12-1/2 508 x 318
20 x 25
508 x 635
20 x 12-1/2 508 x 318
20 x 12-1/2 508 x 318
20 x 25
508 x 635
INSTALLATION INSTRUCTIONS
CAUTION
Electric Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power before removing or installing
power supply board.
LED Board
Jumper
P5 Ionizer
Position
Current (mA)
1.65
2 (1.65)
1.65
2 (1.65)
2.1
1 (2.1)
1.65
2 (1.65)
1.65
2 (1.65)
2.1
1 (2.1)
1.05
4 (1.05)
1.05
4 (1.05)
2.1
1 (2.1)
2.1
1 (2.1)
2.1
1 (2.1)
2.1
1 (2.1)
0.9
3 (1.29)
0.9
3 (1.29)
2.1
1 (2.1)
2.1
1 (2.1)
0.9
3 (1.29)
0.9
3 (1.29)
1.05
4 (1.05)
1.05
4 (1.05)
2.1
1 (2.1)
2.1
1 (2.1)
Replacement Power
Supply (OS no.)
PS1202C00
PS2402C00
PS1202C00
PS2402C00
PS1202C00
PS2402C00
PS1202C00
PS2402C00
PS1202C03
PS1202C03 with 203365
PS1202C03
PS1202C03 with 203365
PS1202C00
PS2402C00
PS1202C00
PS2402C00
PS1202C00
PS2402C00
69-1137EF-01
Air
Flow
Switch
No
Yes

Publicité

Table des Matières
loading

Sommaire des Matières pour Honeywell PS1202C

  • Page 1 PS1202C, PS2402C Replacement Power Supply Kits for Electronic Air Cleaners INSTALLATION INSTRUCTIONS APPLICATION CAUTION Electric Shock Hazard. These kits replace the power supplies with solid-state Can cause electrical shock or equipment performance indicators (SSPI) used in the F50, F52, damage.
  • Page 2 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS INSTALLATION To Remove Old Power Supply Board And Performance Indicator When Installing this Product… Board 1. Read these instructions carefully. Failure to follow NOTE: It is advisable to observe the location of lead- them could damage the product or cause a hazard- wires on the power supply to be replaced.
  • Page 3 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS ONE-CELL MODEL Fig. 4. Power box location on F57 Air Cleaners. Open to access power supply. M33489 Fig. 2. Power supply location on F50 One Cell. PLASTIC CELL HOOKS CELL CONTACT PLATES...
  • Page 4 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS IMPORTANT Do not splice ionizer and collector leads. These ELECTRONIC leads must be unbroken to avoid electrical shock AIR CLEANER through the connector or tape covering the splice.  Route the remaining leads so the red ionizer and black collector leads are separate from the power supply and light leads.
  • Page 5 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS JUNCTION BOX BROWN BROWN LINE VOLTAGE POWER SUPPLY BLACK BLACK TRAY BLACK IONIZER BLACK SHORTING COLLECTOR ON-OFF SWITCH YELLOW TEST BUTTON POWER SUPPLY IONIZER YELLOW BLACK COLLECTOR RPID BOARD 1 2 3 4 5 6 7...
  • Page 6 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS JUNCTION BOX BROWN BROWN LINE VOLTAGE BLACK BLACK POWER SUPPLY TRAY BLACK IONIZER COLLECTOR BLACK SHORTING ON-OFF SWITCH YELLOW POWER SUPPLY BLACK COLLECTOR TEST IONIZER BUTTON YELLOW BLACK RPID BOARD...
  • Page 7 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS JUNCTION BOX BROWN BROWN LINE VOLTAGE POWER SUPPLY BLACK BLACK TRAY BLACK IONIZER COLLECTOR BLACK ON-OFF SWITCH SHORTING YELLOW POWER SUPPLY IONIZER TEST BLACK YELLOW BUTTON COLLECTOR RPID BOARD BLACK...
  • Page 8: Power Supply

    PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS BLACK COLLECTOR RED IONIZER CONTACT BOARD BLACK BLACK POWER SUPPLY BLACK RPID BOARD 1 2 3 4 5 6 7 GRAY TERMINAL STRIP ORANGE FRONT BACK BROWN VIOLET W8600E BLACK...
  • Page 9 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS SSPI PRINTED WIRING BOARD ASSEMBLY WHITE GREEN YELLOW BLUE ORANGE BROWN P19 P12 P13 P17 P15 P14 SSPI WHITE WHITE WHITE CHECK (YELLOW) (RED) WASH (YELLOW) BLACK COLLECTOR RED IONIZER...
  • Page 10 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT PERFORMANCE BOARD SWITCH BLACK BLACK BLACK RPID BOARD (YELLOW) WASH 1 2 3 4 5 6 7 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS...
  • Page 11 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS SSPI PRINTED WIRING BOARD ASSEMBLY WHITE GREEN YELLOW BLUE ORANGE BROWN P19 P12 P13 P17 P15 P14 SSPI WHITE WHITE WHITE CHECK (YELLOW) (RED) WASH (YELLOW) BLACK COLLECTOR RED IONIZER...
  • Page 12 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT PERFORMANCE BOARD SWITCH BLACK BLACK BLACK RPID BOARD (YELLOW) WASH 1 2 3 4 5 6 7 (YELLOW) CHECK (RED) ORANGE...
  • Page 13 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT BOARD BLACK PERFORMANCE SWITCH (YELLOW) WASH (YELLOW) CHECK ORANGE WHITE (RED) BLACK BROWN LAMP WHITE WHITE TERMINAL BOARD FOR POWER SUPPLY CONNECTIONS.
  • Page 14 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS SSPI PRINTED WIRING BOARD ASSEMBLY WHITE GREEN YELLOW BLUE ORANGE BROWN P19 P12 P13 P17 P15 P14 SSPI WHITE WHITE WHITE CHECK (YELLOW) (RED) WASH (YELLOW) BLACK COLLECTOR RED IONIZER...
  • Page 15 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS BLACK COLLECTOR TEST RED IONIZER BUTTON POWER SUPPLY CONTACT PERFORMANCE BOARD SWITCH BLACK BLACK BLACK RPID BOARD (YELLOW) WASH 1 2 3 4 5 6 7 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS...
  • Page 16: Troubleshooting And Service

    PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS CHECKOUT CAUTION The following instructions are for use only by qualified personnel. WARNING Electric Shock Hazard. Tools and Equipment Can cause personal injury or equipment damage. Troubleshooting the electronic air cleaner requires: The following procedures expose hazardous live •...
  • Page 17 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS TROUBLESHOOTING AIR CLEANERS WITH SOLID STATE PERFORMANCE INDICATOR. START TO USE THIS CHART: FOLLOW THE STEPS IN ORDER; DO NOT SKIP AROUND. EACH TIME YOU ISOLATE AND FIX A PROBLEM, GO BACK TO START.
  • Page 18 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS START WARNING RISK OF ELECTRIC SHOCK THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO REDUCE RISK MAKE SURE CELLS OF ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING OTHER THAN CONTAINED IN THE ARE CLEAN, DRY, AND OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
  • Page 19 PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS Modification To Reduce Ozone Odor WARNING Electric Shock Hazard. Can cause personal injury. Always disconnect power before opening the power supply cover. The electronic air cleaner generates a small amount of ozone in normal operation.
  • Page 20 Plymouth, MN 55441-4437 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer.
  • Page 21 Nécessaires de bloc d’alimentation de remplacement PS1202C, PS2402C pour épurateurs d’air électroniques NOTICE D'INSTALLATION APPLICATION MISE EN GARDE Risque de choc électrique. Ces nécessaires remplacent les blocs d’alimentation Peut provoquer des chocs électriques ou avec indicateurs de performance à semi-conducteur endommager le matériel.
  • Page 22: Modèle À Une Cellule

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES Tableau 1. Guide de remplacement du bloc d’alimentation. (suite) Taille nominale de Comm- cellule(s) Modèle Courant Position de Remplacement du bloc utateur électronique(s) d'alimen- d'ionisateur cavalier de d’alimentation d'aéra-...
  • Page 23 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES  Retirer le bornier et le câblage W8600E. Garder les vis pour une utilisation ultérieure. CROCHETS DE CELLULE PLASTIQUES  Sur le F90, déposer le bloc d'alimentation comme suit : PLAQUES DE CONTACT DE CELLULE PRÉFILTRE...
  • Page 24: Installation Du Bloc D'alimentation Neuf

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES Installation du bloc d'alimentation neuf  Lors du remplacement de l'alimentation, consulter le schéma de câblage approprié. Voir les Fig. 7 à Fig. 20.  Installer le nouveau bornier W8600E et le nouveau câblage avec les vis déposés précédemment.
  • Page 25 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES BOÎTIER DE RACCORDEMENT MARRON MARRON TENSION SECTEUR BLOC D’ALIMENTATION NOIR NOIR PLATEAU ROUGE NOIR IONISATEUR ROUGE NOIR TIGE DE COURT-CIRCUIT COLLECTEUR INTERRUPTEUR MARCHE-ARRÊT JAUNE BOUTON DE TEST BLOC D’ALIMENTATION...
  • Page 26 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES BOÎTIER DE RACCORDEMENT MARRON MARRON TENSION SECTEUR NOIR NOIR BLOC D’ALIMENTATION PLATEAU ROUGE NOIR IONISATEUR ROUGE COLLECTEUR NOIR TIGE INTERRUPTEUR MARCHE-ARRÊT DE COURT-CIRCUIT JAUNE BLOC D’ALIMENTATION IONISATEUR COLLECTEUR...
  • Page 27: Interrupteur Marche-Arrêt Jaune

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES BOÎTIER DE RACCORDEMENT MARRON MARRON TENSION SECTEUR NOIR NOIR BLOC D’ALIMENTATION PLATEAU ROUGE NOIR IONISATEUR ROUGE COLLECTEUR NOIR TIGE INTERRUPTEUR MARCHE-ARRÊT JAUNE DE COURT-CIRCUIT BLOC D’ALIMENTATION IONISATEUR ROUGE...
  • Page 28 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES COLLECTEUR NOIR IONISATEUR ROUGE ROUGE PLAQUE À CONTACTS NOIR NOIR BLOC D’ALIMENTATION NOIR CARTE RPID 1 2 3 4 5 6 7 GRIS BORNIER ORANGE AVANT MARRON VIOLET...
  • Page 29 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES ENSEMBLE DE CARTE IMPRIMÉE SSPI BLANC ROUGE VERT JAUNE BLEU ORANGE MARRON P19 P12 P13 P17 P15 P14 SSPI ROUGE BLANC ROUGE BLANC MARCHE BLANC (JAUNE) ROUGE VÉRIFICATION...
  • Page 30 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES COLLECTEUR NOIR BOUTON IONISATEUR ROUGE DE TEST BLOC D’ALIMENTATION ROUGE PLAQUE À CONTACTS COMMUTATEUR DE PERFORMANCE NOIR NOIR NOIR MARCHE CARTE RPID (JAUNE) NETTOYAGE 1 2 3 4 5 6 7 1 BLOC D’ALIMENTATION.
  • Page 31 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES ENSEMBLE DE CARTE IMPRIMÉE SSPI BLANC ROUGE VERT JAUNE BLEU ORANGE MARRON P19 P12 P13 P17 P15 P14 SSPI ROUGE BLANC ROUGE BLANC BLANC MARCHE ROUGE VÉRIFICATION (JAUNE)
  • Page 32 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES COLLECTEUR NOIR BOUTON IONISATEUR ROUGE DE TEST BLOC D’ALIMENTATION ROUGE PLAQUE COMMUTATEUR À CONTACTS DE PERFORMANCE NOIR NOIR NOIR MARCHE CARTE RPID (JAUNE) NETTOYAGE 1 2 3 4 5 6 7 (JAUNE) VÉRIFICATION...
  • Page 33 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES COLLECTEUR NOIR BOUTON IONISATEUR ROUGE DE TEST ROUGE BLOC D’ALIMENTATION PLAQUE À CONTACTS NOIR COMMUTATEUR DE PERFORMANCE MARCHE (JAUNE) NETTOYAGE (JAUNE) VÉRIFICATION ORANGE (ROUGE) BLANC NOIR MARRON 4 AMPOULE BLANC ARRÊT...
  • Page 34 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES ENSEMBLE DE CARTE IMPRIMÉE SSPI BLANC ROUGE VERT JAUNE BLEU ORANGE MARRON P19 P12 P13 P17 P15 P14 SSPI ROUGE BLANC ROUGE BLANC MARCHE BLANC (JAUNE) ROUGE VÉRIFICATION...
  • Page 35 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES COLLECTEUR NOIR BOUTON IONISATEUR ROUGE DE TEST BLOC D’ALIMENTATION ROUGE PLAQUE COMMUTATEUR À CONTACTS DE PERFORMANCE NOIR NOIR NOIR MARCHE CARTE RPID (JAUNE) NETTOYAGE 1 2 3 4 5 6 7 1 BLOC D’ALIMENTATION.
  • Page 36: Outils Et Équipement

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES VÉRIFICATION MISE EN GARDE Les instructions suivantes sont destinées à un AVERTISSEMENT personnel qualifié uniquement. Risque de choc électrique. Outils et équipement Peut causer des blessures et des dommages matériels.
  • Page 37 NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES DÉPANNAGE DES ÉPURATEURS D’AIR AVEC INDICATEUR DE PERFORMANCE À SEMI-CONDUCTEUR. DÉBUT POUR UTILISER CE TABLEAU : SUIVRE LES ÉTAPES DANS L’ORDRE. À CHAQUE FOIS QU’UN PROBLÈME EST ISOLÉ ET RÉSOLU, RECOMMENCER AU DÉBUT.
  • Page 38: Pour Utiliser Ce Tableau

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES AVERTISSEMENT DÉBUT RISQUE DE CHOC ÉLECTRIQUE. CES INSTRUCTIONS DE RÉPARATION SONT RÉSERVÉES À UN PERSONNEL QUALIFIÉ. POUR RÉDUIRE LES RISQUES DE CHOC ÉLECTRIQUE, N'EFFECTUER AUCUNE AUTRE PROCÉDURE DE RÉPARATION S’ASSURER QUE LES...
  • Page 39: Modification Pour Réduire L'odeur D'ozone

    NÉCESSAIRES DE BLOC D’ALIMENTATION DE REMPLACEMENT PS1202C, PS2402C POUR ÉPURATEURS D’AIR ÉLECTRONIQUES En fonctionnement normal, l’épurateur d’air électronique génère une petite quantité d’ozone. Durant la première BORNE DU semaine ou les deux premières semaines de COLLECTEUR fonctionnement, la quantité d'ozone dégagée peut être BORNE DE supérieure en raison des bords coupants présents sur...
  • Page 40: Garantie Limitée De Deux Ans

    GARANTIE LIMITÉE DE DEUX ANS Honeywell garantit ce produit contre tout vice de fabrication ou de matériau dans la mesure où il en est fait une utilisation et un entretien convenables, et ce, pour deux (2) ans à partir de la date d’achat par le consommateur. En cas de défaut ou de mauvais fonctionnement du produit pendant la période de garantie, Honeywell remplacera ou réparera...

Ce manuel est également adapté pour:

Ps2402c

Table des Matières