Installation And Assembly - Grasslin talis II Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Switching capacity
Incandescent lamp load
Halogen lamp load (AC)
Halogen lamp load (LV)
Fluorescent lamp load
LED lamp /
energy-saving lamp

Installation and assembly

Packaging content and options
See Fig. 1
Dimensions
Fig. 2
Detector
Fig. 3
On-wall mounting with on-wall box talis
II SM BOX 20
Fig. 4
Suspended ceiling mounting with inter-
mediate unit talis II FC BOX 20
Location/installation (Fig. 5/6)
• Avoid installing the presence detector in the
vicinity of
− Source of heat (fan heaters, air-conditioning
units, lighting etc.)
− Objects with reflective surfaces (mirrors
etc.)
− Objects that may be moved by the wind
• Avoid direct sunlight.
• The detection range depends on the corre-
sponding installation height:
Installation
Detection range
height
(tangential movement)
3 m
Ø 10 m
6 m
Ø 12 m
9 m
Ø 14 m
12 m
Ø 20 m
8
max. 2200 W
max. 2200 W
max. 1200 VA / 1000 W
max. 1200 VA / 140 μF
max. 800 VA / 600 W
Lens shield
You can shield off undesired areas of detection by
attaching the enclosed lens shield to the lens.
Use scissors to cut the lens shield horizontally or
vertically until you achieve the desired detection
range.
Wiring diagram
Fig. 7
A connected load is controlled by a pres-
ence detector.
LUX
TIME
Fig. 8
The connected load is switched on for
100
an adjustable period of time, either by
10
300
5m
the presence detector or by the staircase
5s
2000
lighting time switch. The "TIME" rotary
knob must be set to
Test
• If inductors are switched (e.g. relay, gate, bal-
lasts), it may be necessary to use a quenching
circuit.
• Parallel switching of a max. of 10 devices.
Installation
WARNING: Disconnect the voltage and secure it
against reconnection!
• Flush mounting
See Fig. 9/10 for the procedure
• Suspended ceiling mounting
with intermediate unit talis II FC BOX 20
See Fig. 11/12/13 for the procedure
• On-wall mounting
with on-wall box talis II SM BOX 20
See Fig. 14/15/16 for the procedure
Function test
• The sensor needs approx. 60 sec. starting time.
• Switch the "TIME" rotary knob to "TEST" and
carry out the function test.
• Note the movement type (Fig. 6).
• The LED and the load are switched on for 3 sec.
each time movement is detected and switched
off 2 sec. before the next detection.
• After the function test, stet the "TIME" rotary
knob to the desired value.
15m
30m
.
1s

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Phb 360-20-1i

Table des Matières