3. Install the mounting bracket on the wall with eight (8)
type "A" screws.
NOTE: Install the mounting bracket and drill the holes in the
wall according to the wall structure and the correspond-
ing mounting points on the mounting bracket. (The
mounting brackets vary according to the model.)
Correct orientation
of Installation Plate
4. Determine the hole positions according to the diagram
detailed in Figures 5A & 5B (15 SEER) and 5C (19 SEER).
Drill one (1) 2.5" hole ( 65mm), slanting slightly to the
outside.
NOTE: Always use wall hole conduit when drilling metal
grid, metal plate, etc.
15 SEER MODELS
C
Figure 5A - 12,000 Btu/h
C
Figure 5B - 18,000 Btu/h
Incorrect orientation
of Installation Plate
Figure 4
Indoor unit outline
D
A
D
A
19 SEER MODELS
C
Btu/h
Model B: 18,000
A: 31" (79 0mm), B:1 0" (265mm), C:4" (1 00mm), D: 6" (151mm)
Figure 5C - 12,000 Btu/h & 18,000 Btu/h
Refrigerant Piping & Condensate Piping
Installation:
5. Drain hose should be installed with a slight downward
slope. (See Figure 6.)
Indoor
Drain hose should NOT be installed as shown in Figure 7.
Do not block water flow by a rise.
6. When connecting extension drain hose, insulate the con-
necting part of the extension drain hose with a shield
pipe. Do not allow the drain hose to be slack.
4
D
Wall
O utdoor
Figure 6
Do not put the end of
drain hose into water.
Figure 7