Check the quartz glass for damage.
Reassemble the whole thing in the reverse order and be sure to install the various components correctly
Switch on the UVC clarifier to check that it works as described above
TFP 10000 UV 11, TFP 15000 UV 13:
Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again
Please observe the above safety measures
Remove the four screws from the top UVC cover on the filter cover.
After removing the screws, remove the UVC cover including the lamp socket and ensure that the O-ring
on the lamp socket is not lost. Do not pull on the power cord in the process
Now it is possible to loosen the fixing nut at the beginning of the quartz glass piston and carefully remove
the quartz glass piston. Take care not to damage the O-ring
Carefully clean the quartz glass piston (5) from the outside and remove any limescale deposits with a
suitable solvent. Rinse off thoroughly before installation.
Check the quartz glass for damage.
Reassemble the whole thing in the reverse order and be sure to install the various components correctly
Switch on the lamp to check that it works as described above.
6.4.
Replacing the UVC tube:
We recommend only having the UVC tube replaced by our qualified personnel.
Damage to the quartz glass piston or the clarifier unit due to improper assembly/disassembly is
not covered by the warranty.
Caution! Do not touch UVC tube (3) directly with your hand; put on cotton gloves!
Do not dispose of old, broken UVC tubes in the household waste. Consult your local disposal company. Do
not use any sharp-edged tools. If the quartz glass piston or O-rings are faulty, they must always be replaced.
TFP 5000 UV 9:
• Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again.
Please observe the above safety measures
Remove the three screws from the top UVC cover on the filter cover.
Disassemble the UVC cover after removing the screws.
Loosen the UVC socket with ballast unit by turning it slightly anti-clockwise (approx. 30°).
Remove the lamp socket, taking care not to lose the O-ring on the quartz piston seat. Do not pull on the
power cord in the process.
Then remove the old UVC tube (3) by gently pulling on the base and replace it with a new original
replacement tube (see item 9 "Service"). Make sure that all parts of the UVC unit are dry
Check the quartz glass for damage.
Reassemble the whole thing in the reverse order and be sure to install the various components correctly
Switch on the lamp to check that it works as described above.
TFP 10000 UV 11, TFP 15000 UV 13:
Disconnect the UVC clarifier and pump from the power supply and secure them against being switched
on again
Please observe the above safety measures
Remove the four screws from the top UVC cover on the filter cover.
After removing the screws, remove the UVC cover including the lamp socket and ensure that the O-ring
on the lamp socket is not lost. Do not pull too hard on the power cord in the process.
Now it is possible to loosen the fixing nut at the beginning of the quartz glass piston and carefully take off
the quartz glass piston.
Then remove the old UVC tube (3) by gently pulling on the base and replace it with a new original
replacement tube (see item 9 "Service"). Make sure that all parts of the UVC unit are dry
Check the quartz glass for damage.
Reassemble the whole thing in the reverse order and be sure to install the various components correctly
Switch on the lamp to check that it works as described above.