NOTE: The restart of a hot lamp normally takes 4-6
minutes pending on the duration time in the recent
performed curing.
NOTE: When the curing process is terminated, do not
turn off the main switch before the cassette has, by the
fan, cooled down for about 5 minutes. Switching off
the dryer too early will shorten the lifetime of the UVA-
lamps.
7.

Maintenance

Before every usage:
Check that
– External cabling is not damaged
– That protection glass in front of lamp is not cracked
or removed
Weekly
Check that UV lamps light up during mobile dryer
operation.
Also, check that all cables are undamaged. A damaged
cable can be a danger to life!
Quarterly
Change the air filter at least once per quarter. If the
outer surface of the filter becomes very dirty, it must be
changed sooner.
8.

Filter replacement

1. Loosen the metal clips on the side plates of the cassette.
2. Remove the used filter.
3. Insert the new filter in such a way that the IRT logo is
visible from the outside.
4. Push the long edges of the filter into the cassette
grooves.
5. Replace the metal clips.
Attention: The filters are disposable and so should not
be cleaned as this will result in the loss of their filtering
capacity.
9.
UV-lamp replacement
Please contact your distributor and order a UV-
[4]
lamp replacementkit including instructions.
[3]
[2]
Reset Lamp timer
After replacing the lamp a reset of the timer needs
to be done.
Reset Lamp timer: Make sure that the main switch
[1]
[5] is turned off. Hold the Start/Stop button [1]
and top right button [2] pressed in simultaneously
while the main switch [5] is turned on. Keep the
[5]
buttons pressed in until a confirmation message
(L1--rESEt.) appears in the top display [4].
714598 rev 4

10. Trouble shooting

Problem
The UVA lamps starts up but shuts down automatically
after a while.
Possible solution
The lamp is worn out. Please contact your distributor
and order a new one.
Problem
The lamp doesn´t start.
Possible solution
Ensure that required cooling time for lamps is fulfilled.
Cooling time increases with dirty air filter.

11. EC Declaration of conformity

According to testing institutes and according to the
machine directive the IRT products in this manual are
not defined as machines, wherefore the machine direc-
tive reference cannot be included in this declaration.
In accordance with EN 17050-1:2010
We,
Hedson Technologies AB
Box 1530
SE-462 28 VÄNERSBORG
Sweden
declare under our sole responsibility that the product
IRT-UVA 1 PrepCure 3 Digital
to which this declaration relates is in conformity with
the following standards
EN 60204-1
EN 61000-6-3
EN 61000-6-2
EN 61000-3-2
EN61000-3-4
EN ISO 9001
in accordance with the provisions of the following
directives in their most current version
2014/35/EU
2014/30/EU
2011/65/EU
Arlöv Sweden, April 21 st 2016
GB
IRT UVA 1 PrepCure 3 Digital
Safety of machinery
Electro-magnetic Compatibility,
Generic Emission Standard.
Electro-magnetic Compatibility,
Generic Immunity Standard.
Electromagnetic Compatibility
Electromagnetic Compatibility
Quality Management System
Low Voltage Directive
Electro-magnetic Compatibility
Directive
Restriction of the use of certain
hazardous substances (RoHS)
5

Publicité

Table des Matières
loading

Table des Matières