UK
ADDITIONAL EXTRA SENSOR
The second sensor has the same sensitivity as the original
integrated into the GasCube.
With the second sensor you get a higher level of security re­
gardless of whether the gases are lighter or heavier than air.
Install the second sensor for a more effective detection of
LPG GAS approximately 30 cm from the floor.

AUX OUTPUT

The GasCube is equipped with an output to connect an
evacuation fan or a gas stop electro­valve.
The output is active during the alarm, it is not active during
the pre­alarm.
AUX output provides a negative signal (– 12 V) with a maxi­
mum current of 500 mA.
If you need to connect a device with higher absorption,
an additional relay must be installed.
IN
PWR
AUX
+
GasCube
white
red
black
12 Volt power supply
+
Additional device
(siren / fan / electro­valve)
max. current 500 mA
+